Components
Service manual
209
EBLA04~08E + EDLA04~08E
Daikin Altherma 3 M
ESIE22-09 – 2022.05
6
Attach the fan motor assembly harness to the top side of the switch box.
7
Install the cable clamps on the expansion valve harness, the two thermistor
harnesses and the 4‑way valve harness.
8
Install and tighten the 3 screws to fix the switch box to the unit.
INFORMATION
The 2 screws at the hydro box side are reachable using a small ratchet ¼ inch and
socket nr. 8 or wrench ¼ inch with a cardan joint.
a
a
a
b
a
Screw
b
Switch box
9
Install the drip proof cover on the switch box.
4.16.10 To close the outdoor unit
NOTICE
Speed nut.
Make sure the speed nut for the top screw is correctly attached to the
service cover.
2
2
2
5×
1
3.55 N.m
a
a
Speed nut