![background image](http://html1.mh-extra.com/html/daikin/ebla04e-v-series/ebla04e-v-series_service-manual_4704429221.webp)
4
|
Components
Service manual
221
EBLA04~08E + EDLA04~08E
Daikin Altherma 3 M
ESIE22-09 – 2022.05
INFORMATION
Some of the thermistors are wired to the same connector. See connector and pin
information of the thermistors at the start of the electrical check procedure and
281]. ALWAYS replace the complete set of thermistors wired
to the same connector.
4
When removing the complete set of thermistors wired to the same connector:
▪
Remove all other thermistors wired to the connector from their thermistor
holder,
▪
Disconnect the thermistor connector,
▪
Remove the complete set of thermistors.
5
To install the thermistor, see
219].
To install the thermistor
1
Install the thermistor as follows:
▪
For air (ambient) thermistor:
Insert the thermistor in the protection tube.
Correctly install the thermistor in the heat exchanger grille recess.
▪
For refrigerant piping thermistors:
Pull the clip and install the thermistor in the specific thermistor holder. Make
sure the clip is in the correct position (blocking the thermistor).
c
a
b
draft – 31/05/2022 15:53
Summary of Contents for EBLA04E V Series
Page 322: ...14 14...
Page 323: ......