EBLA04~08E + EDLA04~08E
Daikin Altherma 3 M
ESIE22-09 – 2022.05
To install the water flow sensor
NOTICE
Check the condition of the O-rings and replace if needed. Apply water or silicon
grease to the O-rings before installation.
1
Mount the O-rings on the water flow sensor.
2
Install the water flow sensor on the inlet pipe. Ensure that the O-ring does
NOT get damaged.
3
Slide the clip over the connection until it snaps into place.
c
a
b
b
a
Water flow sensor connector nut
b
Clip
c
Water flow sensor
4
Install the water flow sensor on the outlet pipe. Ensure that the O-ring does
NOT get damaged.
5
Slide the clip over the connection until it snaps into place.
6
Connect the water flow sensor harness to the water flow sensor.
7
Tighten the water flow sensor connector nut.
INFORMATION
Replace all cable ties that were cut during removal.
8
Open the valve (if equipped) of the water circuit towards the expansion vessel.
CAUTION
Make sure to open the valve (if equipped) towards the expansion vessel, otherwise
the overpressure will be generated.
9
Open the stop valves and add water to the water circuit if needed, see
269].
Is the problem solved?
Action
Yes
No further actions required.
No
Return to the troubleshooting of the
specific error and continue with the
next procedure.