![background image](http://html1.mh-extra.com/html/daikin/ebla04e-v-series/ebla04e-v-series_service-manual_4704429250.webp)
4
|
Components
Service manual
250
EBLA04~08E + EDLA04~08E
Daikin Altherma 3 M
ESIE22-09 – 2022.05
a
d
a
b
b
c
a
Connector
b
Bolt
c
Water pump motor
d
Pump housing
CAUTION
Make sure to correctly install the water pump motor and the seal.
2
Fix the water pump motor by tightening the 4 bolts.
3
Connect the connectors to the water pump motor.
Is the problem solved?
Action
Yes
No further actions required.
No
and continue with the next procedure.
To remove the water pump
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
202].
1
Drain water from the water circuit, see
269].
2
Disconnect the connectors from the water pump motor.