![background image](http://html1.mh-extra.com/html/daikin/ebla04e-v-series/ebla04e-v-series_service-manual_4704429123.webp)
4
|
Components
Service manual
123
EBLA04~08E + EDLA04~08E
Daikin Altherma 3 M
ESIE22-09 – 2022.05
b
Backup heater pipe
c
Backup heater coupling
NOTICE
Check the condition of the O-rings and replace if needed. Apply water or silicon
grease to the O-rings before installation.
3
Install the upper backup heater coupling and install the clip.
a
e
c
g
d
f
b
a
Backup heater thermal protector sensor
b
Air purge valve
c
Clip (upper backup heater pipe)
d
Clip (backup heater coupling)
e
Upper backup heater coupling
f
Backup heater
g
Bracket
INFORMATION
Make sure that the back‑up heater pipe is fully inserted in the back‑up heater
coupling.
a
b
c
a
a
Clip
b
Backup heater pipe
c
Backup heater coupling
NOTICE
Check the condition of the O-rings and replace if needed. Apply water or silicon
grease to the O-rings before installation.
4
Install the clips on the upper and lower backup heater pipe.
5
Connect the ground wire to the switch box using the screw. Tighten the screw.
6
Connect the backup heater connector X12Y.