background image

No, 0010503017

HSU-09HV03/R2(DB)
HSU-12HVE03/R2(DB)
HSU-18HVE03/R2(DB)
HSU-22HVE03/R2(DB)

HSU-07HV03/R2(DB)

Summary of Contents for HSU-12HVE03

Page 1: ...No 0010503017 HSU 09HV03 R2 DB HSU 12HVE03 R2 DB HSU 18HVE03 R2 DB HSU 22HVE03 R2 DB HSU 07HV03 R2 DB...

Page 2: ...2 21 9 22 26 Cautions Parts and functions Operation Maintenance Trouble shooting Contents 1 5 6 8 27...

Page 3: ...disposal services nearest to your house Disposal of the packaging of your new air conditioner Before starting the air conditioner read the information given in the User s Guide caref ully The User s G...

Page 4: ...aximum D B W B Minimum D B W B Outdoor Indoor Outdoor Heating Specifications The machine is adaptive in following situation 10 The power plug and connecting cable must have acquired the local attestat...

Page 5: ...use Please call Sales Service Shop for the Installation Do not attempt to install the air conditioner by yourself because improper works may cause electric shock fire water leakage lnstallation in a i...

Page 6: ...ecially at infants or the aged Do not try to repair or reconstruct by yourself Do not use for the purpose of storage of food art work precise equipment breeding or cultivation CAUTION Take fresh air o...

Page 7: ...p and down air flow Don t adjust it manually Horizontal louver Air filter inside Inlet grille Power plug adjust left and right air flow inside Outlet Anion generator inside For 18k 22k unit the power...

Page 8: ...unction When the remote controller appears abnormal use a sharp pointed article to press this button to reset the remote controller normal 33 RESET Used to set clock and timer setting 8 HOUR button Us...

Page 9: ...ny obstacle as well Don t throw or knock the remoter controller When electronic started type fluorescent lamp or change over type fluorescent lamp or wireless telephone is installed in the room the re...

Page 10: ...antity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room When indoor fan motor is running it has healthy proce...

Page 11: ...e mode of auto operation air conditioner will automatically select Cool or Heat operation according to room temperature 4 Unit stop Press on off button the unit stops Press FAN button For each press f...

Page 12: ...o C if kept depressed it will decrease rapidly Select a desired temperature 4 Fan speed selection 3 Select temp setting 5 Unit stop Air conditioner is running under displayed fan speed When FAN is set...

Page 13: ...Unit stop AUTO LOW MED HI AUTO COOL DRY FAN HEAT Operation Dry Operation 1 Unit start On the displaying board colorful displaying bar will be light blue Air conditioner is running under displayed fan...

Page 14: ...de the unit will not operate in COOL or HEAT mode but only in FAN mode AUTO is not available in FAN mode And temp setting is disabled In FAN mode SLEEP and POWER SOFT operation is not available AUTO L...

Page 15: ...if kept depressed it will increase rapidly Every time the button is pressed temp setting decrease 1o C if kept depressed it will decrease rapidly Select a desired temperature 4 Fan speed selection 3 S...

Page 16: ...ccording to the above positions HEAT AUTO 1 Status display of air sending Horizontal louvers Pos 1 Pos 2 Pos 3 Pos 4 Pos 5 Pos 6 Pos 7 Pos 8 3 Left and right air flow direction For each press of butto...

Page 17: ...1O C Rises 1O C Temp setting Temp setting Unit stop Unit stop In COOL DRY mode In HEAT mode Decreases 2O C Decreases 2O C 1 hr Sleep Operation 2 3 In HEAT mode 1 hours after SLEEP mode starts temp wi...

Page 18: ...Remote controller BLANK TIMER ON TIMER OFF TIMER ON OFF Then select your desired TIMER mode TIMER ON or TIMER OFF or will flash 3 Time setting Press HOUR button Every time the button is pressed time s...

Page 19: ...Press HOUR button Every time the button is pressed time setting increases 1 min if kept depressed it will increase rapidly Every time the button is pressed time setting decreases 1 min if kept depres...

Page 20: ...rs In SOFT operation mode fan speed automatically takes AUTO changes as follows Stop the display at SOFT BLANK POWER Press POWER SOFT button Every time the button is pressed display changes as follows...

Page 21: ...on the position of inlet and outlet grills is fixed 2 In heating it is better to select the mode 3 In cooling it is better to select the mode 4 In cooling and dry using the air conditioner for a long...

Page 22: ...tch in the test operation when the room temperature is below 16 O C do not use it in the normal operation Continue to press the test operation switch for more than 5 seconds After you hear the Pi soun...

Page 23: ...eration If the unit is not to be used for a long time turn off the power supply main switch Use the timer effectively Use the louvers effectively Do not block the air inlet or outlet Maintenance Prope...

Page 24: ...mpletely fixed behind the stopper If the right and left filters are not attached correctly that may cause defects Remote Controller Do not use the following for cleaning Do not use water wipe the cont...

Page 25: ...ing Filter Replancement of Air Purifying Filter NOTE The photocatalyst air purifying filter and the bacteria killing medium air purifying filter will be used based on real situation The photocatalyst...

Page 26: ...for 2 3 hours Put off the power supply cord Take out the batteries from the wireless remote controller Cleaning the body To prevent breeding mold or bad smell be sure to operate at the designated tem...

Page 27: ...e plug insert the plug of the power supply cord into the outlet completely In case of suing exclusive circuit breaker switch on the circuit breaker NO WET HAND EARTHING Operation without filter may ca...

Page 28: ...psed to protect the system When the electric plug is pulled out and reinserted the protection circuit will work for 3 minutes to protect the air conditioner During unit operation or at stop a swishing...

Page 29: ...Precauzioni per l uso 3 Denominazione dei componenti 5 Tasti e display del telecomando 6 Funzionamento Manutenzione 1 9 Guida alla ricerca dei guasti 2 3 Indice 28 2 3 0 4 4...

Page 30: ...cibo opere d arte attrezzature di precisione per allevamento di animali o coltivazione di piante Aerare la stanza di tanto in tanto specialmente se contemporaneamente in funzione un elettrodomestico...

Page 31: ...ale L installazione deve essere eseguita da personale qualifi cato e autorizzato Non tentare di installare l apparecchio da soli Per ragioni di sicurezza il climatizzatore deve essere dota to di messa...

Page 32: ...direzione destra sinistra del flusso d aria Uscita aria Filtro dell aria all interno Ionizzatore all interno Denominazione dei componenti Unit interna Griglia di uscita aria Griglia di aspirazione Tub...

Page 33: ...o automatico 7 Tasto MODE Per selezionare la modalit operativa desiderata Ad ogni pressione del tasto la modalit operativa varia come segue 8 Tasti HOUR impostazione oraria Per regolare l ora dell oro...

Page 34: ...regolare la velocit del ventilatore bassa media alta auto 28 Tasto SWING alto basso Per modificare la direzione del flusso d aria verticalmente verso l al to e verso il basso 29 Tasto SWING sinistra...

Page 35: ...uto il tasto ON OFF il display del telecomando resta spento togliere e inserire di nuovo le batterie Note Una visualizzazione completa o non chiara sul display del telecomando indica che le batterie s...

Page 36: ...l ventilatore Premere il tasto FAN ad ogni pressione la velocit del ventilatore varia come segue Il climatizzatore funzioner con la velocit del flusso d aria selezionata Quan do FAN impostato su AUTO...

Page 37: ...pressione la velocit del ventilatore varia come segue Il climatizzatore funzioner con la velocit del ventilatore selezionata 4 Arresto del climatizzatore Premere il tasto ON OFF il climatizzatore si...

Page 38: ...idificazione Ventilazione Riscaldamento Auto Il deflettore orizzontale osciller secondo lo schema sopra illustrato 2 Direzione del flusso d aria sinistra destra Premere il tasto SWING freccette destra...

Page 39: ...ra ora la tempe ratura ambiente si abbasser di altri due gradi Dopo altre 3 ore la tempera tura ambiente si alzer di 1 C Mantenendo questa stessa temperatura l uni t funzioner per altre tre ore e poi...

Page 40: ...rr visualizzata sul display a cristalli liquidi E possibile impostare il Ti mer nell arco di 24 ore AM si riferisce alla mattina e PM al pomeriggio 4 Conferma dell impostazione Dopo aver impostato cor...

Page 41: ...Ti mer nell arco di 24 ore AM si riferisce alla mattina e PM al pomeriggio 4 Conferma dell impostazione per TIMER ON Dopo aver impostato correttamente l orario premere il tasto TIMER per con fermare...

Page 42: ...e MODALIT OPERATIVA SOFT Modalit consigliabile per ridurre il livello di rumorosit dell apparecchio per esempio quando si dorme o si legge Il funzionamento risulta pi silenzioso in quanto viene contro...

Page 43: ...ativi nell aria neutralizzare i batte ri e accelerare il deposito di polveri e quindi purificare l aria della stanza 3 Funzione ricambio d aria opzionale Premere una volta il tasto FRESH sul display d...

Page 44: ...le griglie inferiori Non sostare direttamente nel flusso d aria 3 Disattivazione della funzione flusso d aria salutare Premere nuovamente il tasto HEALTH AIRFLOW tutte le griglie di aspi razione e usc...

Page 45: ...avviato il Raffreddamento con veloci t del ventilatore alta Dopo 30 minuti il funzionamento di prova termina automaticamente Disattivazione del funzionamento d emergenza o di prova Semplicemente prem...

Page 46: ...climatizzatore non viene usato per un lungo periodo di tempo staccare l alimentazione elettrica Non collocare ostacoli davanti alle griglie di aspirazione e di uscita Utilizzare il Timer in maniera ef...

Page 47: ...zina sgrassanti o detersivi possono danneggiare il rive stimento dell apparecchio Acqua calda sopra i 40 C pu scolorire o deformare le par ti in plastica Pulizia del filtro dell aria 1 Aprire il panne...

Page 48: ...ro dell aria 5 Chiudere il pannello frontale Note Il filtro purificatore anti batterico posizionato sulla parte sinistra dell unit interna mentre il filtro purificatore a rigenerazione solare posizion...

Page 49: ...e la spina nella presa di corrente ATTENZIONE Dopo aver rimosso eventuale polvere dalla spina inserire completamente la spina del cavo di alimentazione dentro la presa di corrente MESSA A TERRA NON CO...

Page 50: ...l fatto che l apparecchio mette in circolazione gli odori provenienti dall ambiente interno quali odore di fumo odore di mobili ecc Durante il funzionamento in modalit Raffreddamento o Deu midificazio...

Reviews: