CyberOptics Corporation
143
Gantry Components
4. Set a target within 5 μm for the following guideway.
Adjusting X-axis and Y-axis Orthogonality
This procedure is to adjust the X-axis and Y-axis orthogonality. This section shows the
procedures performed when the machine is not in the production line.
➢
To adjust the X-axis and Y-axis orthogonality
1. Turn off all electrical power to the system. For more information, refer to the section
2. Place the square granite ruler and indicators. Contact CyberOptics for the part number of the
granite ruler and indicator.
Target within 5 µm
Granite Ruler
Indicators