Chapter 3
:
Replacing Components and Preventive Maintenance
134
SE500
ULTRA
Hardware Manual
Preventive Maintenance
Cleaning the Encoder Strips
Encoder strips are located on the gantry along the X and Y axes. There are two encoder strips for
the X axis. (Left to right)
➢
To clean the encoder strips
1. Turn off all electrical power to the system. For more information, refer to the section
2. Open the SE500
ULTRA
hood.
3. Make sure all motion has stopped.
4. Locate the encoder strips on the X- and Y-axes.
5. Remove any coarse or abrasive particles with clean, dry, compressed air.
Warning:
Make sure the system power is turned off and locked off before working inside the
hood. Gantry motion can pinch or sever objects in its path.
Caution:
The encoder strips can be damaged by abrasive substances and solvents. Follow the
procedure below to avoid scratches or other damage to the encoder strips.