Chapter 3
:
Replacing Components and Preventive Maintenance
148
SE500
ULTRA
Hardware Manual
Other Components
This section contains procedures for replacing the following SE500
ULTRA
system components:
●
Leveling Feet
●
Safety Interlock Switch
Replacing the Safety Interlock Switch
This procedure can be performed with access to the front of the machine in production line.
This section shows the procedure performed when the machine is not in production line.
Parts
Safety Interlock Switch
Safety Interlock Key
➢
To replace the safety interlock switch
1. Turn off all electrical power to the system. For more information, refer to the section
2. Open the SE500
ULTRA
hood.
3. Make sure all motion has stopped.
4. Remove three screws to take off the cover to the safety interlock switch.
Figure 96.
Safety Interlock Switch Access
5. Disconnect the six wires in the box.
6. Remove the strain relief nut and pull the cable out of the switch.
Caution:
Turn the AC main circuit breaker to OFF to shut down all electrical power to the
SE500
ULTRA
unit before starting any replacement operations. See “
page 52 for this procedure.
i
Note:
For Parts Replacement, contact CyberOptics for part numbers.
Safety interlock switch detail.
Disconnect wires (steps 4 through 7
on 148) before removing the switch.
Summary of Contents for SE500ULTRA
Page 1: ...SE500ULTRA Hardware Manual ...
Page 6: ...Contents vi SE500ULTRA Hardware Manual ...
Page 10: ...x SE500ULTRA Hardware Manual This page is intentionally left blank ...
Page 28: ...Chapter 1 System Overview 18 SE500ULTRA Hardware Manual Dimensions Figure 8 Front View ...
Page 30: ...Chapter 1 System Overview 20 SE500ULTRA Hardware Manual ...
Page 184: ...Chapter 5 System Drawings 174 CyberOptics Corporation ...