Chapter 2
:
Installation
38
SE500
ULTRA
Hardware Manual
Connecting SMEMA Cables
Use the SMEMA connections to facilitate board handling between machines in the SMT line.
➢
To connect SMEMA cables
1. Shut down Windows and then push the E-Stop button on the front of the unit.
2. Turn off all electrical power to the system. For more information, refer to “
Figure 24.
SMEMA Connectors
3. Route the SMEMA cables under the SE500
ULTRA
unit to the connectors on the rear.
4. Connect the upstream cable to the upper connector.
5. Connect the downstream cable to the lower connector.
Downstream
SMEMA connector
Upstream
SMEMA connector
Pins
Upstream Cable
Downstream Cable
1 - 2
Machine Ready
Machine Ready
3 - 4
Board Available
Board Available
7 - 8
Failed Board Available
Failed Board Available
Connector Pinout
Back Electrical Panel
Summary of Contents for SE500ULTRA
Page 1: ...SE500ULTRA Hardware Manual ...
Page 6: ...Contents vi SE500ULTRA Hardware Manual ...
Page 10: ...x SE500ULTRA Hardware Manual This page is intentionally left blank ...
Page 28: ...Chapter 1 System Overview 18 SE500ULTRA Hardware Manual Dimensions Figure 8 Front View ...
Page 30: ...Chapter 1 System Overview 20 SE500ULTRA Hardware Manual ...
Page 184: ...Chapter 5 System Drawings 174 CyberOptics Corporation ...