Chapter 1
:
System Overview
12
SE500
ULTRA
Hardware Manual
➢
To configure the conveyor for Board Flow
1. Connect the board stop at the fixed conveyor rail as shown in Figure 7 for Left to Right
configuration which is the default configuration.
2. To change to use the Right to Left configuration, unscrew the two nuts on the board stop.
3. Mirror the board stop diagonally and replace the two nuts on the board stop.
Figure 6.
Board Stop Position for Left-to-Right Configuration
4. Route the cables along the opposite conveyor rail.
5. Connect the board stop to the fixed conveyor rail.
Figure 7.
Left to Right Board Flow Configuration
i
Note:
Set the
ConveyorRightToLeft
value using the Configuration Editor. The value “0’
indicates Left to Right configuration. The value ‘ 1’ indicates Right to Left configuration.
Board Stop
Board Stop
Panel Proximity Sensor (Entry)
Panel Detect Sensor (Exit)
Movable Conveyor Rail
Fixed Conveyor
Rail