CyberOptics Corporation
35
Wiring SE500ULTRA for Power
4. Feed the incoming power lines through the strain-relief connector.
Figure 21.
Electrical Wiring
5. Connect L and N to the connections marked on the lower face of the circuit breaker.
6. Connect the ground wire to one of the green terminals on the terminal block:
a.
Insert a screwdriver to release the crimp-style connector.
b.
Insert the stripped portion of the wire into the connector.
c.
Remove the screwdriver, allowing the connector to crimp the conductor.
d.
Pull the wire to ensure it is secured.
7. Replace the power access cover and secure with four screws.
Pry open the crimping
connector using a
screwdriver and insert
the conductor.
Screwdriver
Stripped wire
NOTE: The SE500
ULTRA
does not comes with power cord.
PE
PE
PE
N2
L2
PE
N1
L1
N
L
N
L
GND
Power Cord
(AWG 14–16)
Voltage (VAC)
110 VAC
240 VAC
Power Cord
(AWG)
14
14-16
L Wire
Brown or Black or Red
N Wire
Blue or White
GND Wire
Yellow or Green or Copper
Caution:
If the ground is not properly connected, the entire machine chassis will float at half
the supply voltage.
Summary of Contents for SE500ULTRA
Page 1: ...SE500ULTRA Hardware Manual ...
Page 6: ...Contents vi SE500ULTRA Hardware Manual ...
Page 10: ...x SE500ULTRA Hardware Manual This page is intentionally left blank ...
Page 28: ...Chapter 1 System Overview 18 SE500ULTRA Hardware Manual Dimensions Figure 8 Front View ...
Page 30: ...Chapter 1 System Overview 20 SE500ULTRA Hardware Manual ...
Page 184: ...Chapter 5 System Drawings 174 CyberOptics Corporation ...