Chapter 3
:
Replacing Components and Preventive Maintenance
128
SE500
ULTRA
Hardware Manual
5. Slide out the middle stator and place it in another ironless container.
6. Slide out the last stator and keep it away from the other two stators.
7. Replace with new stators. Install the last stator first.
8. Tighten with screws using a tightening torque of 110 kgf.cm after apply adequate amount of
threadlocking sealant.
9. Install the middle stator. Tighten with screws using a tightening torque of 110 kgf.cm after
applying adequate amount of threadlocking sealant.
10. Lastly install the first stator. Tighten with screws using a tightening torque of 110 kgf.cm
after adequate amount of applying threadlocking sealant. The direction of the stators must
be in a “North South –North South” direction. Markings are indicated on the stators.
Middle stator
Last stator
All stators removed