background image

innovated security

INSTALLATION INSTRUCTIONS

UN-W2P12

UNII WIRELESS PIR 12 METER

INTRODUCTION

The UN-W2P12 is a fully supervised low-current 

wireless PIR detector that includes an advanced RF 

protocol for secure and reliable system operation.

The UN-W2P12 has a unique ID code - compatible 

with the UNii Wireless Interface Elite that is designed 

to “learn” specifi c IDs and respond only to them.

The UNW2P12 includes selectable 15kg pet immunity 

feature.

The UN-W2P12 includes series of messages for full 

communication administration (Supervision, Tamper, 

Low Batt.) as well as test transmission signals 

(communication, Tamper, alarm).

FEATURES

• 

State-of-the-art 2-way wireless security

• 

UN advanced & secured RF protocol

• 

Low current Technology

• 

Powered by a single 3V Lithium battery

• 

Battery life: up to 3 years

• 

Frequency: 868MHz

• 

Tamper Open/Close transmission

• 

Supervision transmission

• 

Battery status send on every transmission

• 

Bi-Color LED indications for monitoring

• 

Range up to 500m in open space.

• 

Unique ID number

• 

Front and back tamper.

• 

PET immune up to 8m

Removal of front cover

Battery replacement

OPERATION

FIGURE 1

The Wireless PIR detector transmits the following 

events data:

SUPERVISION

 - a periodical transmission every 7 

min. indicates detector’s presence.

ALARM

 - Alarm transmission triggered by PIR 

intrusion detection.

LOW BAT

 – Whenever the battery reaches a pre- set 

low level (~2.4V) Battery Low signal will be sent with 

the next scheduled message (Supervisor, Alarm, etc.).

TAMPER

 – Whenever the cover is removed or placed 

back, a message will be transmitted with “Tamper” 

signal.

REMOVAL OF FRONT COVER 

ID REGISTRATION

Refer to the UNii Wireless Interface Elite installation 

instructions and follow the procedure given there for 

“learning” detector IDs.

Make sure that the UNii keypad is on learning mode 

according to installation instruction.

Place battery as instructed (see fi g. 2) & wait until 

start up LED stops blinking.

Note the LED indications on the device:

• 

Green/red LED flashes alternately – for 15-45 

sec PIR was registered successfully, cover may 

be closed only after verifi cation with UNii panel.

• 

Green LED blinks periodically – Device was not 

signed into UNii Wireless Interface Elite. Repeat 

installation process.

• 

Red LED blinks – for over 20sec Battery voltage 

is critically low. Replace battery.

The UNii keypad has a “RF Signal Strength Indication” 

in order to help the installer to defi ne the best location 

for the detector from RF perspective.

The indication values are “excellent”, “strong”, “poor” 

or “unknown”. If this indication value is “poor” or 

“unknown”, it is a sign for a weak or no RF link and it 

is recommended to fi nd a better installation for the 

UN-W2P12.

RF SIGNAL INDICATION

FIGURE 2

BATTERY PLACEMENT

FIGURE 3

CIRCUIT LAYOUT

Choose a location most likely to intercept an intruder. 

(Our recommendation is a corner installation). See 

detection pattern. The detector detects motion cros-

sing the beam; it is more sensitive detecting motion 

crossing the beams then moving toward the detector.

Recommended mounting height – 1.8m-2.4m.

AVOID THE FOLLOWING LOCATIONS:

• 

Facing direct sunlight.

• 

Facing areas that may change temperature 

rapidly.

• 

Areas where there are air ducts or substantial 

airflows.

The UN-W2P12 performs better when provided with 

a constant and stable environment.

SELECT MOUNTING 

LOCATION 

DETECTION PATTERN

12 x 12m, 90°

1.  LED Enable / Disable:

ON- Position (Up)– enables LED’s indications for 

each transmitted event.

OFF Position (Down) – disable LED’s indications

NOTE: THE STATE OF THE SWITCH “LED” DOES NOT 

AFFECT THE OPERATION OF LED ON START-UP, 

WALK TEST, CRITICAL LOW BAT INDICATION, AND 

DEVICE TROUBLE INDICATION

2.  PULSE - “Sensitivity Adjustment” 

use for setting 

the PULSE count function in order to provide PIR 

sensitivity control according to the environment.

ON – “2” Low sensitivity. For harsh environments. 

OFF – “1” High sensitivity. For stable environments

3.  APS: Automatic Power Saver function

 enables a

battery life span up to 5 years. The detector will

transmit only when the last event has occurred

more than 2 minutes prior to the current one.

4.  PET -“Pet Immunity Adjustment” 

use for setting 

the PET Immune level to 15Kg or 25Kg. 

OFF- Immunity to an animal up to 15 kg

ON - Immunity to an animal up to 25 kg

5.  Range Adjust: “PIR” POTENTIOMETER 

-

adjustment according to protected area range. Use 

the Potentiometer to adjust the detection sensitivity 

between 30% and 100%, according to walk test in the 

protected area. Rotate the potentiometer clockwise to 

increase range, counter-clockwise to decrease range.

After adjusting the sensitivity perform a walk test to 

verify optimum correct sensitivity in the protected 

area.

SETTING THE DETECTOR

(FUTURE DEVELOPMENT)

Reviews: