Chapter V Trigger System
29
Polar:
Click [Polarity] menu key, and the Polarity setup menu will pop up on the right side of the screen:
Fig. 5.14 Runt Trigger Polarity Setup Menu
Click
[
Positive
]
,
[
Negative
]
and
[
Either
]
buttons to select the corresponding polarity setting.
Trigger When
Click [Trigger When] menu key, and the Trigger When setup menu will pop up on the right side of the screen:
Fig. 5.15 Runt Trigger When Setup Menu
Click [Runt Occurs] key to set the trigger time to be Trigger When to Runt Occurs;
Click [Runt Width<], and set the trigger time to be smaller than a certain time value, which can be set by rotating
the Multipurpose b, with a range from 6.4 ns to 12.8 s;
Click [Runt Width>], and set the trigger time to be larger than a certain time value, which can be set by rotating
the Multipurpose b, with a range from 6.4 ns to 12.8 s;
Click [Runt Width=], and set the trigger time to be equal to a certain time value, which can be set by rotating the
Multipurpose b, with a range from 6.4 ns to 12.8 s;
Click [Runt Width
≠
], and set the trigger time to be not equal to a certain time value, which can be set by rotating
the Multipurpose b, with a range from 6.4 ns to 12.8 s.
Runt Pulse Thresholds
Click the menu key, and the Runt Pulse Thresholds setup menu will pop up on the right side of the screen:
Summary of Contents for 4456 Series
Page 10: ...VIII...
Page 55: ...Chapter V Trigger System 45 Fig 5 51 RF Test Signal Example...
Page 69: ...Chapter VII Mathematical Operation 59 Fig 7 10 Advanced Math Example...
Page 71: ...Chapter VIII Display System 61 Fig 8 3 Wfm Palette Menu Fig 8 4 Normal Palette...
Page 72: ...Chapter VIII Display System 62 Fig 8 5 Inverted Palette Fig 8 6 Temperature Palette...
Page 75: ...Chapter VIII Display System 65 Fig 8 12 XY Display Example...
Page 165: ...Chapter XI Protocol Analyzer Option 155 Fig 11 242 1553 Trigger and Analysis Example...