180
ZE-855A,856A
13. STANDARD ADJUSTMENTS
13. STANDARDEINSTELLUNGEN
13. REGLAGES STANDARD
13. AJUSTES ESTANDARES
■
Memory switches 61~88
61
ON
(Do not change)
OFF
62
ON
(Do not change)
OFF
63
ON
(Do not change)
OFF
64
ON
(Do not change)
OFF
65 3-step backtacking
ON
When plan zigzagging is selected, backtacking is 3-step zigzag
OFF Backtacking is same as normal pattern
66 Pattern reset
ON
Returns to start of pattern after treadle depressed backward
OFF Continues sewing pattern after treadle depressed backward
67 Pattern reset for specified patterns
ON
For patterns 5~9, returns to start of pattern after
treadle depressed backward
OFF Continues sewing pattern after treadle depressed backward
68 Blind stitch pattern
ON
Straight-line section is at start of pattern
OFF Zigzag section is at start of pattern
71
ON
(Do not change)
OFF
72
ON
(Do not change)
OFF
73
ON
(Do not change)
OFF
74
ON
(Do not change)
OFF
75
ON
(Do not change)
OFF
76
ON
(Do not change)
OFF
77
ON
(Do not change)
OFF
78
ON
(Do not change)
OFF
81 Variable feed pitch
ON
Sewing patterns with varying feed pitch (T stitch) possible
OFF Normal operation
82 Lower thread counter operation
ON
Lower thread counter operates
OFF Lower thread counter does not operate
83 Lower thread counter warning operation
ON
When stopped in neutral position during
warning operation, machine cannot restart
OFF When treadle is depressed backward during
warning operation, machine cannot restart
84 Lower thread counter warning operation
ON
Starting not prevented during warning operation
OFF Starting prevented during warning operation
85
ON
(Do not change)
OFF
86
ON
(Do not change)
OFF
87
ON
(Do not change)
OFF
88
ON
(Do not change)
OFF