Configuration Mode (ConF)
89
Code
Nam e / De s cription
Adjus tment range
Factory s e tting
FULL
[FULL]
(continued)
SEt-
[SETTINGS]
Inr
0.01
0.1
1
[Ramp increment]
0.1
This parameter is valid for
[Acce le ration]
(ACC)
,
[De ce le ration]
(dEC)
,
[Acce le ration 2]
(AC2)
and
[Decele ra tio n 2]
(dE2)
. See
[Ra mp incre m e nt]
(Inr)
page
170
.
[0,01]
: Ramp up to 99.99 seconds
[0,1]
: Ramp up to 999.9 seconds
[1]
: Ramp up to 6,000 seconds
ACC
[Acceleration]
0.00 to 6,000 s (1)
3.0 s
Time to accelerate from 0 to the
[Rate d motor freq.]
(FrS)
page
86
. To have repeatability in ramps, the value of this parameter
must be set according to the possibility of the application. See
[Acce le ration]
(ACC)
page
170
.
dEC
[Deceleration]
0.00 to 6,000 s (1)
3.0 s
Time to decelerate from the
[Rate d motor freq.]
(FrS)
page
86
to 0. To have repeatability in ramps, the value of this parameter
must be set according to the possibility of the application. See
[De ce le ration]
(dEC)
page
170
.
AC2
*
[Acceleration 2]
0.00 to 6,000 s (1)
5 s
Time to accelerate from 0 to the
[Rate d motor freq.]
(FrS)
page
86
. To have repeatability in ramps, the value of this parameter
must be set according to the possibility of the application. See
[Acce le ration 2]
(AC2)
page
171
.
dE2
*
[Deceleration 2]
0.00 to 6,000 s (1)
5 s
Time to decelerate from the
[Rate d motor freq.]
(FrS)
page
86
to 0. To have repeatability in ramps, the value of this parameter
must be set according to the possibility of the application. See
[De ce le ration 2]
(dE2)
page
171
.
tA1
*
[Begin Acc round]
0 to 100%
10%
Rounding of start of acceleration ramp as a % of the
[Acce le ration]
(ACC)
or
[Acce leration 2]
(AC2)
ramp time. Visible if
[Ramp type]
(rPt)
is set to
[Cust om ize d]
(CUS)
. See
[Begin Acc round]
(tA1)
page
170
.
tA2
*
[End Acc round]
0 to 100%
10%
Rounding of end of acceleration ramp as a % of the
[Acce le ration]
(ACC)
or
[Acce leration 2]
(AC2)
ramp time.
Can be set betw een 0 and 100% -
[Be gin Acc round]
(tA1)
.
Visible if
[Ra mp type]
(rPt)
is set to
[Cust om ize d]
(CUS)
. See
[End Acc round]
(tA2)
page
171
.
tA3
*
[Begin Dec round]
0 to 100%
10%
Rounding of start of deceleration ramp as a % of the
[De ce le ration]
(dEC)
or
[De ce le ration 2]
(dE2)
ramp time. Visible if
[Ramp type]
(rPt)
is set to
[Cust om ize d]
(CUS)
. See
[Begin Dec round]
(tA3)
page
171
.
tA4
*
[End Dec round]
0 to 100%
10%
Rounding of end of deceleration ramp as a % of the
[De ce le ration]
(dEC)
or
[De ce le ration 2]
(dE2)
ramp time.
Can be set betw een 0 and 100% -
[Be gin De c round]
(tA3)
.
Visible if
[Ra mp type]
(rPt)
is set to
[Cust om ize d]
(CUS)
. See
[End Dec round]
(tA4)
page
171
.
LSP
[Low speed]
0 to 599 Hz
0 Hz
Motor frequency at minimum reference, can be set betw een 0 and
[High s pe e d]
(HSP)
page
87
. See
[Low s pe ed]
(LSP)
page
87
.
HSP
[High speed]
0 to 599 Hz
50 Hz
Motor frequency at maximum reference, can be set between
[Low spee d]
(LSP)
and
[Max freque n c y]
(tFr)
. The factory
setting changes to 60 Hz if
[Standard m ot. fre q]
(bFr)
is set to
[60Hz NEM A]
( 0)
. See
[High s pe e d]
(HSP)
page
87
.
Parameters described in this page can be accessed by:
DRI- > CONF > FULL > SET-
Summary of Contents for ER24 Series
Page 6: ...6 Table of Contents ...
Page 14: ...16 ...
Page 34: ...Overview 36 ...
Page 40: ...42 ...
Page 74: ...Monitoring Mode MOn 76 ...
Page 241: ......
Page 278: ...Configuration Mode ConF 278 Access Level See Access Level LAC page 280 ...
Page 294: ...Interface ItF 294 ...
Page 298: ...298 Open Save as trA ...
Page 302: ...Multipoint Screen 302 ...
Page 304: ...304 ...
Page 306: ...Maintenance 306 ...
Page 316: ...Diagnostics and Troubleshooting 316 ...
Page 318: ...318 ...
Page 340: ...Index of Parameter Codes 340 ...
Page 343: ......
Page 344: ...Index of Parameter Codes 342 ER24_Programming_Manual_EN_01 2017 ...