Configuration Mode (ConF)
159
Code
Nam e / De s cription
Adjus tment range
Factory s e tting
FbrM
[FB start mode]
[No]
(nO)
2 s
WARNING
UNANTICIPATED EQUIPMENT OPERATION
Depending on the s etting of this param eter, function blocks m ay be im m ediately executed.
•
Verify that this s etting does not res ult in uns afe conditions.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
Allow s to choose the different ways of starting the Function blocks application.
Note :
Modifications of this parameter are not taken into account if the Function blocks application is running.
[No]
(nO)
: Function blocks application is controlled by
[FB com m and]
(FbCd)
parameter
[Ye s ]
(YES)
: Function blocks application sw itches to Run automatically at drive pow er on
[LI1]
(LI1)
: Function blocks application switches to Run on a rising edge of the logic input. It sw itch to Stop on falling edge of
the logic input.
[...]
(...)
: See the assignment conditions on page
153
(not
[OL10]
(OL01)
to
[OL10]
(OL10)
).
nO
YES
LI1
...
FbSM
[Stop FB Stop motor]
[Fre e w heel]
(YES)
nO
WARNING
LOSS OF CONTROL
If
[Stop FB stop motor]
(FbSM)
is s et to
[No]
(nO)
, the m otor will not s top when the program will be
s topped.
•
Only s et this param eter to
[No]
(nO)
if you have im plem ented appropriate alternative s top functions .
Failure to follow these instructions can result in death, serious injury, or equipment damage.
Allow s to setup the w ay of working of the drive w hen function blocks are stopped.
[Ignore ]
(nO)
: The drive does not stop
[Fre e w heel]
(YES)
: Motor stops in freew heel
[Ram p s top]
(rMP)
: Ramp stop
[Fas t s top]
(FSt)
: Fast stop
[DC inje ction]
(dCI)
: DC injection
YES
rMP
FSt
dCI
FbdF
StOP
IGn
[FB on drive fault]
[Stop]
(StOP)
Behavior of function blocks w hen the drive trips.
[Stop]
(StOP)
: Function blocks stops w hen the drive trips, outputs are realeased
[Ignore]
(IGn)
: Function blocks continue to w ork when the drive trips (except CFF and INFE)
FbA-
[INPUTS ASSIGNMENTS]
IL01
[Logic input 1 assignment]
[No]
(nO)
nO
Possible assignment for the Function block logic input.
[No]
(nO)
: Not assigned
[No drive flt]
(FLt)
: Drive fault detection status (relay normally energized, and de-energized in the event of an error)
[Fre q. Th. attain.]
(FtA)
: Frequency threshold attained (
[Fre q. thre s hold]
(Ftd)
page
102
)
[Fre q. Th. 2 attaine d]
(F2A)
: Frequency threshold 2 attained (
[Fre q. thre s hold 2]
(F2d)
page
102
)
[Re f.1 channe l]
(Fr1)
Reference source 1
[Re f.2 channe l]
(Fr2)
Reference source 2
[ch1 active ]
(Cd1)
: Command channel = channel 1 (for
[Cmd sw itching]
(CSS)
)
[ch2 active ]
(Cd2)
: Command channel = channel 2 (for
[Cmd sw itching]
(CSS)
)
[Ref.1 B channe l]
(Frlb)
: Referenc e channel = channel 1b (for
[Ref. 2 switching]
(rFC)
)
[Ye s ]
(YES)
: Yes
[LI1]
(LI1)
: Logical input LI1
[...]
(...)
: See the assignment conditions on page
153
FLt
FtA
F2A
Fr1
Fr2
Cd1
Cd2
Fr1b
YES
LI1
...
IL--
[Logic input x assignment]
[No]
(nO)
All the Function Blocks logic inputs available on the drive are processed as in the example for
[Logic input 1 as s ignm e nt]
(IL01)
above, up to
[Logic input 10 as s ignm e nt]
(IL10)
.
Summary of Contents for ER24 Series
Page 6: ...6 Table of Contents ...
Page 14: ...16 ...
Page 34: ...Overview 36 ...
Page 40: ...42 ...
Page 74: ...Monitoring Mode MOn 76 ...
Page 241: ......
Page 278: ...Configuration Mode ConF 278 Access Level See Access Level LAC page 280 ...
Page 294: ...Interface ItF 294 ...
Page 298: ...298 Open Save as trA ...
Page 302: ...Multipoint Screen 302 ...
Page 304: ...304 ...
Page 306: ...Maintenance 306 ...
Page 316: ...Diagnostics and Troubleshooting 316 ...
Page 318: ...318 ...
Page 340: ...Index of Parameter Codes 340 ...
Page 343: ......
Page 344: ...Index of Parameter Codes 342 ER24_Programming_Manual_EN_01 2017 ...