Monitoring Mode (MOn)
54
Code
Nam e / De s cription
Unit
IOM-
[I/O MAP]
(continued)
FSI-
[FREQ. SIGNAL IMAGE]
Frequency signal image.
This menu is visible only on graphic display terminal.
PFrC
[RP input]
Hz
Filtered customer pulse input frequency reference.
Follow ing parameters are visible on the graphic display terminal by pressing the ENT key on the parameter.
PIA
[RP assignment]
Pulse input assignment. If no functions have been assigned,
[No]
(nO)
is displayed.
Identical to
[AI1 as s ignm ent]
(AI1A)
page
52
.
PIL
[RP min value]
kHz
RP minimum value. Pulse input scaling parameter of 0%.
PFr
[RP max value]
kHz
RP maximum value Pulse input scaling parameter of 100%.
PFI
[RP filter]
ms
Interference filtering pulse input cutoff time of the low -filter.
MOn-
[1.2 MONITORING]
(continued)
SAF-
[MONIT. SAFETY]
For more details on Integrated Safety Functions, please refer to dedicated Safety manual.
StOS
IdLE
StO
FLt
[STO status]
Status of the Safe Torque Off safety function.
[Idle ]
(IdLE)
: STO not in progress
[Safe s top]
(StO)
: STO in progress
[Fault]
(FLt)
: STO error detected
SLSS
nO
IdLE
WAIt
Strt
SS1
SLS
StO
FLt
[SLS status]
Status of the Safely-limited speed safety function.
[Not config.]
(nO)
: SLS not configured
[Idle ]
(IdLE)
: SLS not in progress
[SLS w ait tim e ]
(WAlt)
: SLS w aiting for activation
[SLS start]
(Strt)
: SLS in transient state
[Safe ram p]
(SS1)
: SLS ramp in progress
[Spd lim ite d]
(SLS)
: SLS speed limitation in progress
[Safe s top]
(StO)
: SLS safe torque off request in progress
[Fault]
(FLt)
: SLS error detected
SS1S
nO
IdLE
SS1
StO
FLt
[SS1 status]
Status of the Safe Stop 1 safety function.
[Not config.]
(nO)
: SS1 not configured
[Idle ]
(IdLE)
: SS1 not in progress
[Safe ram p]
(SS1)
: SS1 ramp in progress
[Safe s top]
(StO)
: SS1 safe torque off request in progress
[Fault]
(FLt)
: SS1 error detected
SMSS
nO
oFF
Fti
Fto
[SMS status]
Status of the Safe Maximum Speed safety function.
[Not Se t]
(nO)
: SMS not set
[Activ e]
(Off)
: SMS active
[Interna l Err.]
(Fti)
: SMS internal error
[M ax Spe e d]
(Fto)
: Maximum Speed reached
Parameters described in this page can be accessed by:
DRI- > MON- > IOM- > FSI-
Summary of Contents for ER24 Series
Page 6: ...6 Table of Contents ...
Page 14: ...16 ...
Page 34: ...Overview 36 ...
Page 40: ...42 ...
Page 74: ...Monitoring Mode MOn 76 ...
Page 241: ......
Page 278: ...Configuration Mode ConF 278 Access Level See Access Level LAC page 280 ...
Page 294: ...Interface ItF 294 ...
Page 298: ...298 Open Save as trA ...
Page 302: ...Multipoint Screen 302 ...
Page 304: ...304 ...
Page 306: ...Maintenance 306 ...
Page 316: ...Diagnostics and Troubleshooting 316 ...
Page 318: ...318 ...
Page 340: ...Index of Parameter Codes 340 ...
Page 343: ......
Page 344: ...Index of Parameter Codes 342 ER24_Programming_Manual_EN_01 2017 ...