Monitoring Mode (MOn)
71
Code
Nam e / De s cription
Unit
SF02
[SAFF Subcode 2]
(1)
Safety fault subregister 02
Application Watchdog Management detected error register
Bit0 = 1 : Fast task detected error
Bit1 = 1 : Slow task detected error
Bit2 = 1 : Application task detected error
Bit3 = 1 : Background task detected error
Bit4 = 1 : Safety fast task/input detected error
Bit5 = 1 : Safety slow task/input detected error
Bit6 = 1 : Safety app task/input detected error
Bit7 = 1 : Safety app task/treatment detected error
Bit8 = 1 : Safety background task detected error
Bit9
: Reserved
Bit10 : Reserved
Bit11 : Reserved
Bit12 : Reserved
Bit13 : Reserved
Bit14 : Reserved
Bit15 : Reserved
SF03
[SAFF Subcode 3]
(1)
Safety fault subregister 03
Bit0 = 1 : Debounce time out
Bit1 = 1 : Input not consistent
Bit2 = 1 : Consistency check - state machine detected error
Bit3 = 1 : Consistency check - debounce timeout corrupted
Bit4 = 1 : Response time data detected error
Bit5 = 1 : Response time corrupted
Bit6 = 1 : Undefined consumer queried
Bit7 = 1 : Configuration detected error
Bit8 = 1 : Inputs are not in nominal mode
Bit9
: Reserved
Bit10 : Reserved
Bit11 : Reserved
Bit12 : Reserved
Bit13 : Reserved
Bit14 : Reserved
Bit15 : Reserved
SF04
[SAFF Subcode 4]
(1)
Safety fault subregister 04
[Safe Torque Off]
StO
detected error register
Bit0 = 1 : No signal configured
Bit1 = 1 : State machine detected error
Bit2 = 1 : Internal data detected error
Bit3
: Reserved
Bit4
: Reserved
Bit5
: Reserved
Bit6
: Reserved
Bit7
: Reserved
Bit8 = 1 : SMS overspeed detected error
Bit9 = 1 : SMS internal detected error
Bit10
: Reserved
Bit11 = 1 : GDL internal detected error 1
Bit12 = 1 : GDL internal detected error 2
Bit13 : Reserved
Bit14
: Reserved
Bit15
: Reserved
(1) Hexadecimal values are displayed on the Graphic display terminal
Example:
SFFE =
0x0008
in Hexadecimal
SFFE = Bit
3
Summary of Contents for ER24 Series
Page 6: ...6 Table of Contents ...
Page 14: ...16 ...
Page 34: ...Overview 36 ...
Page 40: ...42 ...
Page 74: ...Monitoring Mode MOn 76 ...
Page 241: ......
Page 278: ...Configuration Mode ConF 278 Access Level See Access Level LAC page 280 ...
Page 294: ...Interface ItF 294 ...
Page 298: ...298 Open Save as trA ...
Page 302: ...Multipoint Screen 302 ...
Page 304: ...304 ...
Page 306: ...Maintenance 306 ...
Page 316: ...Diagnostics and Troubleshooting 316 ...
Page 318: ...318 ...
Page 340: ...Index of Parameter Codes 340 ...
Page 343: ......
Page 344: ...Index of Parameter Codes 342 ER24_Programming_Manual_EN_01 2017 ...