Monitoring Mode (MOn)
55
Code
Nam e / De s cription
Unit
GdLS
[GDL status]
Status of the Guard Door Locking safety function.
nO
[Not Se t]
(nO)
: GDL not set
oFF
[Inact ive ]
(Off)
: GDL inactive
Std
[Short De lay]
(Std)
: Short Delay In Progress
LGD
[Long De lay]
(LGd)
: Long Delay In Progress
oN
[Active ]
(LGd)
: GDL active
LFt
[Inte rnal Err.]
(LGd)
: GDL internal error
SFFE
[Safety fault reg.]
Safety function error register.
Bit0 = 1: Logic inputs debounce time-out (verify value of debounce time LIDT according to the application)
Bit1 Reserved
Bit2 = 1: Motor speed sign has changed during SS1 ramp
Bit3 = 1: Motor speed has reached the frequency limit threshold during SS1 ramp.
Bit4: Reserved
Bit5: Reserved
Bit6 = 1: Motor speed sign has changed during SLS limitation
Bit7 = 1: Motor speed has reached the frequency limit threshold during SS1 ramp.
Bit8: Reserved
Bit9: Reserved
Bit10: Reserved
Bit11: Reserved
Bit12: Reserved
Bit13 = 1: Not possible to measure the motor speed (verify the motor w iring connection)
Bit14 = 1: Motor ground short-circuit detected (verify the motor w iring connection)
Bit15 = 1: Motor phase to phase short-circuit detected (verify the motor w iring connection)
MOn-
[1.2 MONITORING]
(continued)
MFb-
[MONIT. FUN. BLOCKS]
For more details on Function Blocks, please refer to dedicated Function Blocks manual.
FbSt
[FB status]
Function Block Status.
IdLE
[Idle ]
(IdLE)
: Idle state
CHEC
[Che ck prog.]
(CHEC)
: Check program state
StOP
[Stop]
(StOP)
: STOP state
InIt
[Init]
(InIt)
: Initialization state
rUn
[Run]
(rUn)
: RUN state
Err
[Error]
(Err)
: Error state
FbFt
[FB fault]
Status of the function blocks execution.
nO
[No]
(nO)
: No error detected
Int
[Interna l]
(Int)
: Internal error detected
bIn
[Binary file ]
(bIn)
: Binary error detected
InP
[Inte rn para.]
(InP)
: Internal parameter error detected
PAr
[Para. RW]
(PAr)
: Parameter access error detected
CAL
[Calculation]
(CAL)
: Calculation error detected
tOAU
[TO AUX]
(tOAU)
: TimeOut AUX task
tOPP
[TO s ynch]
(tOPP)
: TimeOut in PRE/POST task
AdL
[Bad ADLC]
(AdL)
: ADLC w ith bad parameter
In
[Input assign.]
(In)
: Input not configured
FbI-
[FB IDENTIFICATION]
bUEr
*
[Program version]
Program user version. Can be accessed if
[FB s tatus ]
(FbSt)
is not set to
[Idle ]
(IdLE)
.
bnS
*
[Program size]
Program file size. Can be accessed if
[FB s tatus ]
(FbSt)
is not set to
[Idle ]
(IdLE)
.
Parameters described in this page can be accessed by:
DRI- > MON- > SAF-
Summary of Contents for ER24 Series
Page 6: ...6 Table of Contents ...
Page 14: ...16 ...
Page 34: ...Overview 36 ...
Page 40: ...42 ...
Page 74: ...Monitoring Mode MOn 76 ...
Page 241: ......
Page 278: ...Configuration Mode ConF 278 Access Level See Access Level LAC page 280 ...
Page 294: ...Interface ItF 294 ...
Page 298: ...298 Open Save as trA ...
Page 302: ...Multipoint Screen 302 ...
Page 304: ...304 ...
Page 306: ...Maintenance 306 ...
Page 316: ...Diagnostics and Troubleshooting 316 ...
Page 318: ...318 ...
Page 340: ...Index of Parameter Codes 340 ...
Page 343: ......