Configuration Mode (ConF)
214
PID PRESET REFERENCES
Code
Nam e / De s cription
Adjus tment range
Factory s e tting
FUn-
[APPLICATION FUNCT.]
(continued)
PrI-
[PID PRESET REFERENCES]
Function can be accessed if
[PID fe e dback as s .]
(PIF)
page
210
is assigned.
Pr2
nO
LI1
...
[2 preset PID ref.]
[No]
(nO)
If the assigned input or bit is at 0, the function is inactive.
If the assigned input or bit is at 1, the function is active.
[No]
(nO)
: Not assigned
[LI1]
(LI1)
: Logical input LI1
[...]
(...)
: See the assignment conditions on page
153
Pr4
[4 preset PID ref.]
[No]
(nO)
Check that
[2 pre s e t PID re f.]
(Pr2)
has been assigned before assigning this function.
Identical to
[2 pre s e t PID re f.]
(Pr2)
page
212
.
If the assigned input or bit is at 0, the function is inactive.
If the assigned input or bit is at 1, the function is active.
rP2
*
(1)
[Preset ref. PID 2]
[M in PID re fe rence]
(PIP1)
to
[M ax PID re fe re nce ]
(PIP2)
(2)
300
This parameter can be accessed if
[2 pre s e t PID re f.2]
(Pr2)
is assigned.
rP3
*
(1)
[Preset ref. PID 3]
[M in PID re fe rence]
(PIP1)
to
[M ax PID re fe re nce ]
(PIP2)
(2)
600
This parameter can be accessed if
[3 pre s e t PID re f.]
(Pr3)
is assigned.
rP4
*
(1)
[Preset ref. PID 4]
[M in PID re fe rence]
(PIP1)
to
[M ax PID re fe re nce ]
(PIP2)
(2)
900
This parameter can be accessed if
[4 pre s e t PID re f.]
(Pr4)
is assigned.
(1) The parameter can also be accessed in the
[SETTINGS]
(SEt-)
menu.
(2) If a graphic display terminal is not in use, values greater than 9,999 w ill be displayed on the 4-digit display w ith a period
mark after the thousand digit, for example, 15.65 for 15,650.
These parameters only appear if the corresponding function has been selected in another menu. When the parameters can
also be accessed and adjusted from w ithin the configuration menu for the corresponding function, their description is detailed
in these menus, on the pages indicated, to aid programming.
Parameter that can be modified during operation or w hen stopped.
Parameters described in this page can be accessed by:
DRI- > CONF > FULL > FUN- > PRI-
*
Summary of Contents for ER24 Series
Page 6: ...6 Table of Contents ...
Page 14: ...16 ...
Page 34: ...Overview 36 ...
Page 40: ...42 ...
Page 74: ...Monitoring Mode MOn 76 ...
Page 241: ......
Page 278: ...Configuration Mode ConF 278 Access Level See Access Level LAC page 280 ...
Page 294: ...Interface ItF 294 ...
Page 298: ...298 Open Save as trA ...
Page 302: ...Multipoint Screen 302 ...
Page 304: ...304 ...
Page 306: ...Maintenance 306 ...
Page 316: ...Diagnostics and Troubleshooting 316 ...
Page 318: ...318 ...
Page 340: ...Index of Parameter Codes 340 ...
Page 343: ......
Page 344: ...Index of Parameter Codes 342 ER24_Programming_Manual_EN_01 2017 ...