Configuration Mode (ConF)
232
MULTIMOTORS / MULTICONFIGURATIONS
Motor or configuration switching
[MULTIMOTORS/CONFIG.]
(MMC-)
The drive m ay contain up to 3 configurations , which can be s aved us ing the
[FACTORY SETTINGS]
(FCS- )
m enu, page
81.
Each of thes e configurations can be activated rem otely, enabling adaptation to:
•
2 or 3 different m otors or m echanisms (m ultimotor m ode)
•
2 or 3 different configurations for a s ingle m otor (m ulticonfiguration m ode)
The two s witching m odes cannot be com bined.
Note:
The following conditions MUST be obs erved:
•
Switching m ay only take place when s topped (drive locked). If a s witching request is s ent during operation,
it will not be executed until the next s top.
•
In the event of m otor s witching, the following additional conditions apply:
- When the m otors are s witched, the power and control term inals concerned m ust als o be s witched as
appropriate.
- The m axim um power of the drive m us t not be exceeded by any of the m otors .
•
All the configurations to be s witched m ust be set and saved in advance in the s ame hardware configuration,
this being the definitive configuration (option and communication cards). Failure to follow this instruction can
caus e the drive to lock on an
[Incorrect config.]
(CFF)
s tate.
Menus and parameters switched in multimotor mode
•
[SETTINGS]
(SEt-)
•
[MOTOR CONTROL]
(drC-)
•
[INPUTS / OUTPUTS CFG]
(I_O-)
•
[COMMAN D ]
(CtL-)
•
[APPLICATION FUNCT.]
(
Fun-
)
with the exception of the
[MULTIMOTORS/CONFIG.]
function (to be
configured once only)
•
[FAULT MANAGEMENT]
(FLt)
•
[MY MENU]
•
[USER CONFIG.]
: The nam e of the configuration s pecified by the us er in the
[FACTORY SETTINGS]
(FCS-)
m enu
Menus and parameters switched in multiconfiguration mode
As in m ultim otor m ode, except for the m otor param eters that are com m on to the 3 configurations :
•
Rated current
•
Therm al current
•
Rated voltage
•
Rated frequency
•
Rated s peed
•
Rated power
•
IR com pens ation
•
Slip com pensation
•
Synchronous m otor parameters
•
Type of therm al protection
•
Therm al s tate
•
The auto-tuning param eters and m otor parameters that can be acces s ed in expert m ode
•
Type of m otor control
Note:
No other m enus or param eters can be s witched.
Parameters described in this page can be accessed by:
DRI- > CONF > FULL > FUN- > MMC-
Summary of Contents for ER24 Series
Page 6: ...6 Table of Contents ...
Page 14: ...16 ...
Page 34: ...Overview 36 ...
Page 40: ...42 ...
Page 74: ...Monitoring Mode MOn 76 ...
Page 241: ......
Page 278: ...Configuration Mode ConF 278 Access Level See Access Level LAC page 280 ...
Page 294: ...Interface ItF 294 ...
Page 298: ...298 Open Save as trA ...
Page 302: ...Multipoint Screen 302 ...
Page 304: ...304 ...
Page 306: ...Maintenance 306 ...
Page 316: ...Diagnostics and Troubleshooting 316 ...
Page 318: ...318 ...
Page 340: ...Index of Parameter Codes 340 ...
Page 343: ......
Page 344: ...Index of Parameter Codes 342 ER24_Programming_Manual_EN_01 2017 ...