Configuration Mode (ConF)
102
Code
Nam e / De s cription
Adjus tment range
Factory s e tting
*
Torque limitation in generator mode, as a % or in 0.1% increments of the rated torque in accordance with the
[Torque increment]
(IntP)
parameter, page
216
.
See page
216
.
trH
*
[Traverse freq. high]
0 to 10 Hz
4 Hz
Traverse high. See page
242
.
trL
*
[Traverse freq. low]
0 to 10 Hz
4 Hz
Traverse low . See page
242
.
qSH
*
[Quick step High]
0 to
[Trave rs e fre q. high]
(trH)
0 Hz
Quick step high. See page
242
.
qSL
*
[Quick step Low]
0 to
[Trave rs e freq. low]
(trL
0 Hz
Quick step low . See page
242
.
Ctd
[Current threshold]
0 to 1.5 In (1)
In (1)
Current threshold for
[I attaine d]
(CtA)
function assigned to a relay or a logic output (see page
138
). See page
252
.
ttH
[High torque thd.]
-300% to +300%
100%
High torque threshold for
[High tq. att.]
(ttHA)
function assigned to a relay or a logic output (see page
138
), as a % of the
rated motor torque. See page
253
.
ttL
[Low torque thd.]
-300% to +300%
50%
Low torque threshold for
[Low tq. att.]
(ttLA)
function assigned to a relay or a logic output (see page
138
), as a % of the rated
motor torque. See page
253
.
FqL
*
[Pulse warning thd.]
0 Hz to 20,000 kHz
0 Hz
Speed threshold measured by the
[FREQUENCY M ETER]
(FqF-)
function, page
266
, assigned to a relay or a logic output
(see page
138
). See page
253
.
Ftd
[Freq. threshold]
0.0 to 599 Hz
HSP
Motor frequency threshold for
[Fre q.Th.att.]
(FtA)
function assigned to a relay or a logic output (see page
138
), or used by the
[PARA M. SET SWITC HIN G ]
(MLP-)
function, page
230
. See page
253
.
F2d
[Freq. threshold 2]
0.0 to 599 Hz
HSP
Motor frequency threshold for
[Freq. th.2 attained]
(F2A)
function assigned to a relay or a logic output (see page
138
), or used
by the
[PARAM . SET SWITCHING]
(MLP-)
function, page
230
. See page
253
.
FFt
*
[Freewheel stop Thd]
0.2 to 599 Hz
0.2 Hz
Speed threshold below which the motor w ill sw itch to freewheel stop.
This parameter supports switching from a ramp stop or a fast stop to a freewheel stop below a low speed threshold.
It can be accessed if
[Type of stop]
(Stt)
is set to
[Fast stop]
(FSt)
or
[Ra mp stop]
(rMP)
and if
[Brak e assignm e nt ]
(bLC)
and
[Auto DC inje ction]
(AdC)
are not configured. See page
173
.
ttd
[Motor therm. level]
0 to 118%
100%
Threshold for motor thermal alarm (logic output or relay). See page
255
.
JPF
[Skip Frequency]
0 to 599 Hz
0 Hz
Skip frequency. This parameter helps to prevent prolonged operation within an adjustable range around the regulated frequency.
This function can be used to help to prevent a speed, w hich would cause resonance, being reached. Setting the function to 0
renders it inactive. See page
183
.
JF2
[Skip Frequency 2]
0 to 599 Hz
0 Hz
Parameters described in this page can be accessed by:
DRI- > CONF > FULL > SET-
Summary of Contents for ER24 Series
Page 6: ...6 Table of Contents ...
Page 14: ...16 ...
Page 34: ...Overview 36 ...
Page 40: ...42 ...
Page 74: ...Monitoring Mode MOn 76 ...
Page 241: ......
Page 278: ...Configuration Mode ConF 278 Access Level See Access Level LAC page 280 ...
Page 294: ...Interface ItF 294 ...
Page 298: ...298 Open Save as trA ...
Page 302: ...Multipoint Screen 302 ...
Page 304: ...304 ...
Page 306: ...Maintenance 306 ...
Page 316: ...Diagnostics and Troubleshooting 316 ...
Page 318: ...318 ...
Page 340: ...Index of Parameter Codes 340 ...
Page 343: ......