Configuration Mode (ConF)
141
Use of analog output AO1 as a logic output
Analog output AO1 can be us ed as a logic output, by as s igning DO1. In this cas e, when s et to 0, this output
corres ponds to the AO1 m in. value (0 V, or 0 m A for exam ple), and when s et to 1 to the AO1 m ax. value (10
V, or 20 m A for exam ple).
The electrical characteris tics of this analog output rem ain unchanged. As thes e characteris tics are different
from logic output characteris tics , check that it is s till com patible with the intended application.
Code
Nam e / De s cription
Adjus tment range
Factory s e tting
I_O-
[INPUTS / OUTPUTS CFG]
(continued)
dO1-
[DO1 CONFIGURATION]
dO1
bLC
LLC
OCC
EbO
tSY
dCO
OL01
...
OL10
[DO1 assignment]
[No]
(nO)
Identical to
[R1 As s ignm e nt]
(r1)
page
138
w ith the addition of the follow ing parameter values (show n for information only
as these selections can only be configured in the
[APPLICATION FUNCT.]
(FUn-)
menu):
[Brk control]
(bLC)
: Brake contactor control
[Input cont.]
(LLC)
: Line contactor control
[Output cont]
(OCC)
: Output contactor control
[End re e l]
(EbO)
: End of reel(traverse control function)
[Sync. w obble ]
(tSY)
: "Counter w obble" synchronization
[DC charging]
(dCO)
: DC bus precharging contactor control
[OL01]
(OL01)
: Function blocks: Logical Output 01
...
[OL10]
(OL10)
: Function blocks: Logical Output 10
dO1d
[DO1 delay time]
0 to 60,000 ms (1)
0 ms
The delay cannot be set for the
[No drive flt]
(FLt)
,
[Brk control]
(bLC)
,
[Output cont.]
(OCC)
and
[Input cont.]
(LLC)
assignments, and remains at 0.
The change in state only takes effect once the configured time has elapsed, w hen the information becomes true.
dO1S
POS
nEG
[DO1 active at]
[1 ]
(POS)
Configuration of the operating logic:
[1]
(POS)
: State 1 w hen the information is true
[0]
(nEG)
: State 0 w hen the information is true
The configuration
[1 ]
(POS)
cannot be modified for the
[No drive flt]
(FLt)
,
[Brk control]
(bLC)
and
[Input cont.]
(LLC)
assignments.
dO1H
[DO1 holding time]
0 to 9,999 ms
0 ms
The holding time cannot be set for the
[No drive flt]
(FLt)
,
[Brk control]
(bLC)
and
[Input cont]
(LLC)
assignments, and
remains at 0.
The change in state only takes effect once the configured time has elapsed, w hen the information becomes false.
(1) 0 to 9,999 ms then 10.00 to 60.00 s on the integrated display terminal.
Parameters described in this page can be accessed by:
DRI- > CONF > FULL > I_O- > DO1-
Summary of Contents for ER24 Series
Page 6: ...6 Table of Contents ...
Page 14: ...16 ...
Page 34: ...Overview 36 ...
Page 40: ...42 ...
Page 74: ...Monitoring Mode MOn 76 ...
Page 241: ......
Page 278: ...Configuration Mode ConF 278 Access Level See Access Level LAC page 280 ...
Page 294: ...Interface ItF 294 ...
Page 298: ...298 Open Save as trA ...
Page 302: ...Multipoint Screen 302 ...
Page 304: ...304 ...
Page 306: ...Maintenance 306 ...
Page 316: ...Diagnostics and Troubleshooting 316 ...
Page 318: ...318 ...
Page 340: ...Index of Parameter Codes 340 ...
Page 343: ......
Page 344: ...Index of Parameter Codes 342 ER24_Programming_Manual_EN_01 2017 ...