Condition
Cause
Solution
Fault Displayed.
Fault Occurred.
See fault code troubleshooting table for
more details.
Display shows Accel or Run.
Maximum Motor Current setting
(QST07) set too low.
Review acceleration ramp settings.
Motor loading too high and/or current not
dropping below 175% FLA indicating
that the motor has not come up to speed.
Reduce load on motor during starting.
Motor FLA (QST01) or CT ratio
(FUN03) parameter set incorrectly.
Verify that Motor FLA and CT ratio
parameters are set correctly.
Abnormally low line voltage.
Fix cause of low line voltage.
A mechanical or supplemental brake is
still engaged.
Verify that any external brakes are
disengaged.
Motor Hums before turning.
Initial current (QST06) to low.
Increase initial current.
Motor FLA (QST01) is incorrect
Review Motor FLA set point.
CT ratio (FUN03) is incorrect
Review CT ratio set point.
Condition
Cause
Solution
Motor accelerates too quickly.
Ramp time 1 (QST08) too short.
Increase ramp time.
Initial current (QST06) set too high.
Decrease Initial current.
Maximum current (QST07) set too high.
Decrease Maximum current.
Kick start current (CFN11) too high.
Decrease or turn off Kick current.
Kick start time (CFN12) too long.
Decrease Kick time.
Motor FLA (QST01) or CT ratio
(FUN03) parameter set incorrectly.
Verify that Motor FLA and CT ratio
parameters are set correctly.
Starter Type parameter (FUN07) set
incorrectly.
Verify that Starter Type parameter is set
correctly.
Motor accelerates too slowly.
Maximum Motor Current setting (QST07)
set too low.
Review acceleration ramp settings.
Motor loading too high.
Reduce load on motor during starting.
Motor FLA (QST01) or CT ratio
(FUN03) parameter set incorrectly.
Verify that Motor FLA and CT ratio
parameters are set correctly.
Abnormally low line voltage.
Fix cause of low line voltage.
Ramp time to long.
Decrease ramp time.
Summary of Contents for RediStart EXEXMVRMX3 Series
Page 2: ......
Page 10: ......
Page 11: ...1 Introduction 1...
Page 17: ...2 Technical Specifications 7...
Page 27: ...3 Installation 17...
Page 48: ......
Page 49: ...4 Keypad Operation 39...
Page 59: ...5 Parameter Groups 49...
Page 67: ...6 Parameter Description 57...
Page 122: ...NOTES 112 6 PARAMETER DESCRIPTION...
Page 123: ...7 Theory of Operation 113...
Page 155: ...NOTES 145 7 THEORY OF OPERATION...
Page 156: ...146 7 THEORY OF OPERATION...
Page 157: ...8 Troubleshooting Maintenance 147...
Page 185: ...NOTES 175 8 TROUBLESHOOTING MAINTENANCE...
Page 186: ......
Page 187: ...Appendices 177...
Page 213: ...203 APPENDIX H 3 YEAR WARRANTY...
Page 221: ...Publication History Revision Date ECO 00 12 15 06 Initial Release...