109
6 - PARAMETER DESCRIPTION
Description
The Miscellaneous Commands parameter is used to issue various commands to the MX
3
starter.
The Reset Run Time command resets the user run time meters back to zero (0).
The Reset kWh command resets the accumulated kilowatt-hour and megawatt-hour meters back to zero (0).
The Reflash Mode command puts the MX
3
into a reflash program memory mode. The reflash mode can only
be entered if the MX
3
starter is idle. When the reflash mode is entered, the MX
3
waits to be programmed.
The onboard LED display shows “FLSH”. The remote display is disabled after entering reflash mode. The
MX
3
does not operate normally until reflash mode is exited. Reflash mode may be exited by cycling control
power.
The Store Parameters command allows the user to copy the parameters into non-volatile memory as a backup.
If changes are being made, store the old set of parameters before any changes are made. If the new settings do
not work, the old parameter values can be loaded back into memory.
The Load Parameters command loads the stored parameters into active memory.
The Factory Reset command restores all parameters to the factory defaults. The default values can be found
in chapter 5.
The standard BIST command will put the starter into the unpowered BIST test. See section 8.9 on page 168.
z
NOTE:
The powered BIST test is only offered in the Low Voltage systems.
Time and Date Format
FUN 23
LCD Display
Range
LCD
Description
mm/dd/yy 12h
month/day/year 12 hour
mm/dd/yy 24h
month/day/year 24 hour
yy/mm/dd 12h
year/month/day 12 hour
yy/mm/dd 24h
year/month/day 24 hour
dd/mm/yy 12h
day/month/year 12 hour
dd/mm/yy 24h
day/month/year 24 hour
Description
Sets the date display format and 12 hour or 24 hour time display.
z
NOTE:
The system clock does not recognize daylight savings time.
Time
FUN 24
LCD Display
Description
Sets the present time.
See Also
Time and Date parameter (FUN 23) on page 109.
Date
FUN 25
LCD Display
Description
Sets the present date.
See Also
Time and Date parameter (FUN 23) on page 109.
FUN: T/D Format
23
mm/dd/yy 12h
FUN:
Time
24
present time
FUN:
Date
25
present date
Summary of Contents for RediStart EXEXMVRMX3 Series
Page 2: ......
Page 10: ......
Page 11: ...1 Introduction 1...
Page 17: ...2 Technical Specifications 7...
Page 27: ...3 Installation 17...
Page 48: ......
Page 49: ...4 Keypad Operation 39...
Page 59: ...5 Parameter Groups 49...
Page 67: ...6 Parameter Description 57...
Page 122: ...NOTES 112 6 PARAMETER DESCRIPTION...
Page 123: ...7 Theory of Operation 113...
Page 155: ...NOTES 145 7 THEORY OF OPERATION...
Page 156: ...146 7 THEORY OF OPERATION...
Page 157: ...8 Troubleshooting Maintenance 147...
Page 185: ...NOTES 175 8 TROUBLESHOOTING MAINTENANCE...
Page 186: ......
Page 187: ...Appendices 177...
Page 213: ...203 APPENDIX H 3 YEAR WARRANTY...
Page 221: ...Publication History Revision Date ECO 00 12 15 06 Initial Release...