7.4.2
TruTorque Deceleration
Overview
TruTorque deceleration control is a closed loop deceleration control. This allows TruTorque deceleration to
be more consistent in cases of changing line voltage levels and varying motor load conditions. TruTorque
deceleration is best suited to pumping and compressor applications where pressure surges, such as water
hammer, must be eliminated. The MX
3
linearly reduces the motor's torque to smoothly decelerate the motor
and load. TruTorque deceleration is very easy to use with only two parameters to set.
Ending Level
The Decel End Level parameter sets the ending torque level for the TruTorque deceleration ramp profile.
A typical TruTorque decel end level setting is between 10% and 20%. If the motor stops rotating before the
deceleration time has expired, increase this parameter value. If the motor is still rotating when the
deceleration time has expired, decrease this parameter value.
Decel Time
The decel time sets the ramp time between the motor torque level when stop was commanded and the decel
end torque level.
If the motor stops rotating before the decel time has expired, decrease the decel time parameter. If the motor
is still rotating when the decel time expires, increase the decel time parameter.
132
7 - THEORY OF OPERATION
Motor
Torque
Time
Decel Time
End Torque
Level
Stop command
Motor Torque
Before Stop
Command
Figure 39: TruTorque Deceleration
Summary of Contents for RediStart EXEXMVRMX3 Series
Page 2: ......
Page 10: ......
Page 11: ...1 Introduction 1...
Page 17: ...2 Technical Specifications 7...
Page 27: ...3 Installation 17...
Page 48: ......
Page 49: ...4 Keypad Operation 39...
Page 59: ...5 Parameter Groups 49...
Page 67: ...6 Parameter Description 57...
Page 122: ...NOTES 112 6 PARAMETER DESCRIPTION...
Page 123: ...7 Theory of Operation 113...
Page 155: ...NOTES 145 7 THEORY OF OPERATION...
Page 156: ...146 7 THEORY OF OPERATION...
Page 157: ...8 Troubleshooting Maintenance 147...
Page 185: ...NOTES 175 8 TROUBLESHOOTING MAINTENANCE...
Page 186: ......
Page 187: ...Appendices 177...
Page 213: ...203 APPENDIX H 3 YEAR WARRANTY...
Page 221: ...Publication History Revision Date ECO 00 12 15 06 Initial Release...