BE1-CDS240 ASCII Command Interface
11-19
RD-YVAR
Command
Purpose:
Report yesterday's Forward and Reverse demand vars
Syntax:
RD-YVAR
Example:
RD-YVAR
Reference:
Section
6,
Reporting and Alarm Functions, Demand Functions
RD-YWATT
Command
Purpose:
Report yesterday's Forward and Reverse demand watts
Syntax:
RD-YWATT
Example:
RD-YWATT
Reference:
Section
6,
Reporting and Alarm Functions, Demand Functions
RE
Command
Purpose:
Report all energy data
Syntax:
RE
Example:
RE
Reference:
Section
6,
Reporting and Alarm Functions, Energy Data
RE-KVARH
Command
Purpose:
Read/Reset/Preset 3 Phase KiloVarHours in primary units
Syntax:
RE-KVARH[={pos kvarh},{neg kvarh}]
Example:
RE-KVARH or RE-KVARH=100,10 or RE-KVARH=0,0
Reference:
Section
6,
Reporting and Alarm Functions, Energy Data
RE-KWH
Command
Purpose:
Read/Reset/Preset 3 Phase KiloWattHours in primary units
Syntax:
RE-KWH[={pos kwh},{neg kwh}]
Example:
RE-KWH or RE-KWH=100,10 or RE-KWH=0,0
Reference:
Section
6,
Reporting and Alarm Functions, Energy Data
RF
Command
Purpose:
Read/Reset Fault Report Data
Syntax:
RF[-n/NEW][=0/TRIG] where n=record # or NEW = new records
Example:
RF (displays a directory of all fault reports in memory)
RF-23 (view summary report for fault record 23)
RF-NEW (view summary report for newest fault record since RF=0 reset)
RF=0 (reset NEW fault counter)
RF=TRIG (Manually Trigger a fault record)
Reference:
Section
6,
Reporting and Alarm Functions, Fault Reporting
RG
Command
Purpose:
Report General information
Syntax:
RG
Example:
RG
Reference:
Section
6,
Reporting and Alarm Functions, General Status Reporting
RG-101STAT
Command
Purpose:
Report 101 status
Syntax:
RG-101STAT
Example:
RG-101STAT
Reference:
Section
6,
Reporting and Alarm Functions, General Status Reporting
Summary of Contents for BE1-CDS240
Page 2: ......
Page 8: ...vi BE1 CDS240 Introduction 9365200990 Rev F This page intentionally left blank ...
Page 38: ...1 28 BE1 CDS240 General Information 9365200990 Rev F This page intentionally left blank ...
Page 40: ...ii BE1 CDS240 Quick Start 9365200990 Rev F This page intentionally left blank ...
Page 152: ...ii BE1 CDS240 Metering 9365200990 Rev F This page intentionally left blank ...
Page 226: ...iv BE1 CDS240 Application 9365200990 Rev F This page intentionally left blank ...
Page 286: ...ii BE1 CDS240 Security 9365200990 Rev F This page intentionally left blank ...
Page 290: ...9 4 BE1 CDS240 Security 9365200990 Rev F This page intentionally left blank ...
Page 292: ...ii BE1 CDS240 Human Machine Interface 9365200990 Rev F This page intentionally left blank ...
Page 306: ...10 14 BE1 CDS240 Human Machine Interface 9365200990 Rev F This page intentionally left blank ...
Page 308: ...ii BE1 CDS240 ASCII Command Interface 9365200990 Rev F This page intentionally left blank ...
Page 342: ...11 34 BE1 CDS240 ASCII Command Interface 9365200990 Rev F This page intentionally left blank ...
Page 349: ...Figure 12 5 Horizontal Rack Mount Front View 9365200990 Rev F BE1 CDS240 Installation 12 5 ...
Page 361: ...Figure 12 17 Typical DC Connection Diagrams 9365200990 Rev F BE1 CDS240 Installation 12 17 ...
Page 372: ...12 28 BE1 CDS240 Installation 9365200990 Rev F This page intentionally left blank ...
Page 468: ...13 92 BE1 CDS240 Testing and Maintenance 9365200990 Rev F This page intentionally left blank ...
Page 512: ...14 42 BE1 CDS240 BESTCOMS Software 9365200990 Rev F This page intentionally left blank ...
Page 544: ...ii BE1 CDS240 Terminal Communication 9365200990 Rev F This page intentionally left blank ...
Page 550: ...ii BE1 CDS240 Settings Calculations 9365200990 Rev F This page intentionally left blank ...
Page 578: ...D 28 BE1 CDS240 Settings Calculations 9365200990 Rev F This page intentionally left blank ...
Page 579: ......