M470039-01 REV-F
Page 83
LOCAL TRANSIENT OPERATION
LCL Opera tion:
STEP Selection
MENU/LOCAL
→
LOAD CONTROL
→
STEP PARAM.
→
STEP
→
STEP AUTO
→
STEP ONCE
OTHER TRANSIENT OPERATION SELECTIONS
Remote Only – Trigger Opera tion
CONT Hot Key – Continuous Opera tion
TOGGLE Hot Key – Toggle Opera tion
SINGLE Hot Key – Pulse Opera tion
STEP Hot Key – Step Opera tion
TRIGGER Hot Key – Front Pa nel Trigger
CONTINUOUS MODE
In continuous mode, the eLoa d input switches between 2 user defined levels; ma in a nd tra nsient. The duty cycle a nd
frequency a re user defined.
Typica l applica tion: Testing the Loa d Regula tion (Effect) of a power Supply, defined a s the volta ge change in dc output
due to a cha nge in loa d current from minima l resista nce (closed circuit) to ma ximum resista nce (open circu it). The PLW
ca n be progra mmed to switch between a ny two current levels.
LCL Opera tion:
1.
Using the mode hot keys, select opera ting mode (CC, CV, CR, CP)
2.
Set the MAIN level by holding down the encoder a nd rota te to cha nge the va lue or enter numerica lly.
3.
Set the Tra nsient level by pressing the “PEAK” hot key a nd edit the va lue using the encoder or enter ma nually.
4.
Select Continuous transient operation by pressing the “CONT” hot key.
5.
Set the duty cycle and frequency by pressing the “DUTY” and “FREQ” hot keys and tapping t he encoder to edit
ea ch. The duty cycle ca n be set from 2% to 98% a nd the frequency from 0.1Hz to 10 KHz. Rota te the encoder
clockwise or counterclockwise to cha nge va lues or enter ma nua lly.
6.
Set the Rising a nd Fa lling Slew Time by pressing “SLEW,” rota te the encoder to select option, ta p the encoder
to edit slew time value and press “ENTER” to confirm value entry.
7.
To begin the continuous tra nsient opera tion, press the “PULSE” hot key (pulse hot key will blink) a nd then press
the “INPUT” hot key to activa te the Continuous transient operation.
i
t
Transient
Level
Main
Level
i
Summary of Contents for Amrel PLA 2U
Page 2: ......
Page 4: ...M470039 01 REV F Page 3 This is page intentionally left blank...
Page 6: ...M470039 01 REV F Page 5 This page intentionally left blank...
Page 8: ...M470039 01 REV F Page 7 This page intentionally left blank...
Page 132: ...M470039 01 REV F Page 131 SEVEN SPECIFICATIONAND POWER CURVE COMMON SPECIFICATIONS...
Page 141: ...M470039 01 REV F Page 140...
Page 161: ......
Page 162: ......