M470039-01 REV-F
Page 47
Model Type
Fuse Rating
Specification
Location
PLW6K
2.5A/250V
Slow Blow
Externa l Fuse (Benea th the AC recepta cle)
PLW9K
4A/250V
Slow Blow
Externa l Fuse (Benea th the AC recepta cle)
PLW12K
4A/250V
Slow Blow
Externa l Fuse (Benea th the AC recepta cle)
PLW18K
4A/250V
Slow Blow
Externa l Fuse (Benea th the AC recepta cle)
PLW24K
6.3A/250V
Slow Blow
Externa l Fuse (Benea th the AC recepta cle)
PLW36K
6.3A/250V
Slow Blow
Externa l Fuse (Benea th the AC recepta cle)
PLW48K - Slave
10A/250V
Slow Blow
Externa l Fuse (Benea th the AC recepta cle)
PLW48K - Master
6.3A/250V
Slow Blow
Externa l Fuse (Benea th the AC recepta cle)
PLW60K - Slave
10A/250V
Slow Blow
Externa l Fuse (Benea th the AC recepta cle)
PLW60K - Master
6.3A/250V
Slow Blow
Externa l Fuse (Benea th the AC recepta cle)
PLA-2U
2.5A/250V
Slow Blow
Externa l Fuse (Benea th the AC recepta cle)
PLA-3U
4A/250V
Slow Blow
Externa l Fuse (Benea th the AC recepta cle)
PLA-4U
6.3A/250V
Slow Blow
Externa l Fuse (Benea th the AC recepta cle)
PLA-6U
8A/250V
Slow Blow
Externa l Fuse (Benea th the AC recepta cle)
PLA-8U-Master
10A/250V
Slow Blow
Externa l Fuse (Benea th the AC recepta cle)
PLA-8U-Slave
6.3A/250V
Slow Blow
Externa l Fuse (Benea th the AC recepta cle)
TABLE 2.2 – FUSE REPLACEMENT SPECIFICATIONS
AC INPUT POWER CONNECTION
Disconnect AC power from the instrument before removing the cover. Even with the front panel power switch in
the OFF position, live line voltages are exposed whe n the cover is removed and the AC cord is attached. Re pairs
must be made by experienced service technicians only.
NOTE: REMOVING THE TOP COVER OR DISASSEMBLING THE UNIT WILL VOID THE WARRANTY.
JJJJJJ
There is a pote ntial shock hazard if the electronic load chassis a nd cover are not connec ted to a n electrical ground
via the safety ground in the AC input connector. Ensure that the electronic load is connected to a grounde d AC
outlet with the recommended AC input connector configured for the available line voltage.
AC INPUT CONNECTOR AND VOLTAGE SELECTION
To prevent damage to the electronic load, turn off AC power to the unit before changing from one AC input
voltage range to another. Example 115Vac to 230Vac.
eLoa d series ha s a n a uto ra nge selection function. This function a llows you to connect to either low or high AC input
volta ge without ma king a ny a djustment to the unit.
WARNING
WARNING
CAUTION
Summary of Contents for Amrel PLA 2U
Page 2: ......
Page 4: ...M470039 01 REV F Page 3 This is page intentionally left blank...
Page 6: ...M470039 01 REV F Page 5 This page intentionally left blank...
Page 8: ...M470039 01 REV F Page 7 This page intentionally left blank...
Page 132: ...M470039 01 REV F Page 131 SEVEN SPECIFICATIONAND POWER CURVE COMMON SPECIFICATIONS...
Page 141: ...M470039 01 REV F Page 140...
Page 161: ......
Page 162: ......