M470039-01 REV-F
Page 121
8. STEP TIME UNIT
This function allows user to select the step time base unit from millisecond to second, which enhanced the
maximum dwell time (step time) from 65535ms to 65535s per step point. Up to 256 step points are user
programmable. This function will help user to perform long term dynamic loading burn in type of applications
or similar.
Local Control
MENU
LOAD CONTROL
STEP PARAM.
→
MODE
→
STEP
→
STEP AUTO
→
STEP ONCE
→
COUNT
→
1 ~ INFINITY
→
TIME UNIT
→
MILLISECOND
→
SECOND
Remote Programming
STEP:TIM[e]:UNIT
This comma nd selects the time ba se unit for STEP Opera tion between millisecond or second.
Command Syntax
STEP:TIM:UNIT <Action Number>
Parameters
<Action Number>
0: millisecond
1: second
Query Syntax
TRIG:ACT:PROT?
Returned Parameters
0 |1
Default
0: millisecond
9. OVERPOWER WARNING MESSAGE (OP):
The eLoa d ha s a n Overpower Protection function set a t 105% of ra ted power. If the power ba sed on DC input termina ls
volta ge a nd current exceeds 105% of ra ted power, the unit will displa y a wa rning messa ge “OP” a nd the loa d will limit
input current level to ma inta in the input power to prevent unit from over overloa d. Over tempera ture protection ma y trip
if the input power exceeds the ra ted power persistently
.
Local Control
NONE
Remote Programming
NONE
Summary of Contents for Amrel PLA 2U
Page 2: ......
Page 4: ...M470039 01 REV F Page 3 This is page intentionally left blank...
Page 6: ...M470039 01 REV F Page 5 This page intentionally left blank...
Page 8: ...M470039 01 REV F Page 7 This page intentionally left blank...
Page 132: ...M470039 01 REV F Page 131 SEVEN SPECIFICATIONAND POWER CURVE COMMON SPECIFICATIONS...
Page 141: ...M470039 01 REV F Page 140...
Page 161: ......
Page 162: ......