M470039-01 REV-F
Page 63
3. SYNTAX MODE--press ENTER key, use
select the synta x mode (PEL or PLW/PLA) then press ENTER
4. EOS CODE----------pre ss ENTER key, use
to set end of interfa ce code then press ENTER.
5. BUZZER-----------press ENTER key, use
to select ON / OFF then press ENTER.
6. PANEL LOCK
7. ETHERNET-------press ENTER key, use
to select ADRESS/NETMASK/GATEWAY; press ENTER.
E: Authenticate Menu
- press ENTER key:
* Use
to select the next menu setting then press ENTER key to enter the selected menu.
* Use
CLEAR
key to ba ck spa ce or to correct the wrong va lue.
1. SERIAL NO.
----------press ENTER key. Seria l NO. should sta rt with 000B87xxxxxx.
2. INTERFACE------
press ENTER key. GPIB/ETHER/USB should be displa y a ccording to customer’s order.
3. CODE--------------
press ENTER key, Input the code from AMETEK, then press ENTER.
LOAD CONTROL MENU
STEP PARAMETERS
Selects the number of Step Count (0 - 65535 & infinity) a nd the different Step Modes (STEP, STEP AUTO, a nd STEP
ONCE)
MEASURE SENSE
This fea ture a llows selection of loca l sense or remote sense of volta ge. Remote sense a llows volta ge to be mea sured a t a
different sense point tha n the bus ba rs to prevent la rge volta ge drops over lengthy wires. If the volta ge rea ding between
the remote sense a nd bus ba r differ by grea ter tha n a set threshold, Remote Sense Fa ult (RSF) will trigger a nd shutdown
the input.
Note: The eLoad’s voltage measuring points (positive and negative) can be configured to two locations. One is from the
power input terminals called Local; the other is from the remote sense terminal block in the rear panel called Remote
(Remote option is only available in certain models). The purpose of the Re mote sense is for more accurate voltage
measurement when longer cables are used (large voltage drop caused by long cables).
MEAS. BUFFER STABLE READ BACK
For AC coupled DC input signa ls, the rea d ba ck meter ma y displa y a n unsta ble rea ding. Do not be a la rmed, the rea d ba ck
rea ding upda te ra te ca n be slowed down for a more sta ble rea ding. Only 8 or 16 mea s. buffer setting is suggested to be
selected, to ensure the correct mea surements a re upda ted properly.
PORT 0
A genera l purpose output port tha t genera tes a TTL compa tible signa l; a ctive high (5V) when port is on a nd ina ctive low
(0V) when port is turned off. The PORT 0 fea ture ca n be used to control exte rna l devices such a s a DC Conta ctor or a
rela y. To ena ble PORT 0, simply follow LOAD CONTROL
→
PORT 0
→
ON.
1: SERIAL NO.
2: INTERFACE
3: CODE
Summary of Contents for Amrel PLA 2U
Page 2: ......
Page 4: ...M470039 01 REV F Page 3 This is page intentionally left blank...
Page 6: ...M470039 01 REV F Page 5 This page intentionally left blank...
Page 8: ...M470039 01 REV F Page 7 This page intentionally left blank...
Page 132: ...M470039 01 REV F Page 131 SEVEN SPECIFICATIONAND POWER CURVE COMMON SPECIFICATIONS...
Page 141: ...M470039 01 REV F Page 140...
Page 161: ......
Page 162: ......