M470039-01 REV-F
Page 67
BOOT INPUT
Boot Input a llows the input to be a utomatically turned on once the unit is powered on. By defa ult, Boot Input is
dea ctiva ted.
LOAD PROFILE MENU
The profile menu a llows 4 different profiles (0~3) to sa ve a ll current loa d configura tions. As a fa ctory default, profile 0
& 3 a re our fa ctory defa ult profile a nd profile 1 is our synta x profile.
DISPLAY MENU
Displa y Mode:
V + I (Volta ge + Current)
V + C (V “C” operand)
V + P (Volta ge + Power)
V + R (Volta ge + Resista nce)
I + C (C “C” operand)
I + P (C Power)
P + C (Power +“C” opera nd)
I + R (C Resista nce)
R + P (Resista nce + Power)
R + C (Resi “C” operand)
V + T (Volta ge + Tempera ture)
I + T (C Tempera ture)
R + T (Resista nce + Tempera ture)
P + T (Power + Tempera ture)
C + T (“C” o Temperature)
The LCD displa y module of the eLoa d ca n be configured to the different mea suring combina tions.
Press the "Menu/Loca l" key. Turn the encoder
to select the Displa y, a nd then press the "ENTER" key a nd turn the
encoder
to select the desired function. Press the “ENTER” key to confirm the selection. Press “CLEAR” key to
esca pe the Displa y Mode.
C OPERAND FOR BATTERY TESTING
“C” Value:
1.0000A
The eLoa d provides the “C” operand. This is especia lly useful for ba ttery testing applica tions that use “C” a s the ba ttery
ca pacity unit. The user ca n avoid troublesome ca lcula tions by monitoring a nd testing the ba ttery directly. After the user
changes the displa y combina tion to V + C, a ll current va lues entered and/or mea sured will be in “C” automa tica lly. The
Current value will be scaled according to its value in C units, for example if a “C” value of 10 A is entered, a main value
setting of 20 A will be represented a s 2 C.
Press the "Menu/Loca l" key, select displa y mode a nd then press ENTER. Turn the encoder
to select the "C" va lue.
Press the "ENTER" key, input the desired value, and then press "ENTER". Then Press “CLEAR” to exit the “C” operand
mode.
SYSTEM FUNCTIONS MENU
To enter a va lue for a pa rticula r function, plea se follow the correct key sequence indica ted under the System Menu a bove.
Press the "Menu/Loca l" to enter the ma in menu tree then turn the encoder
keys to se lect the System Menu. Then
press the “ENTER” and turn the encoder
to further select the next level of commands. Press the Enter key to
confirm the selection.
You can press the "Clear” key repeatedly or the “Local” key at any time to exit the function or mode level.
GPIB FUNCTION
The eLoa d provides the GPIB/SCPI interfa ce control ca pa bility. The following a re user configura ble GPIB options:
PRIMARY ADDR:
0
→
31
Prima ry a ddress for GPIB interfa ce ha s a ra nge from 0 to 31.
Press the "Menu/Loca l" key then turn the encoder
to select the System function, a nd select GPIB Address then press
the "ENTER" key. Turn the encoder
to se lect the PRIMAR Y ADDR function by pressin g enter, turn the encoder
Summary of Contents for Amrel PLA 2U
Page 2: ......
Page 4: ...M470039 01 REV F Page 3 This is page intentionally left blank...
Page 6: ...M470039 01 REV F Page 5 This page intentionally left blank...
Page 8: ...M470039 01 REV F Page 7 This page intentionally left blank...
Page 132: ...M470039 01 REV F Page 131 SEVEN SPECIFICATIONAND POWER CURVE COMMON SPECIFICATIONS...
Page 141: ...M470039 01 REV F Page 140...
Page 161: ......
Page 162: ......