INPUT TERMINAL CONNECTOR
JJJJJJ
There is a shock hazard at the load when using an electronic load with a rated output greater than 40V. To
protect personnel against contact with hazardous voltages, ensure that the load, including connections, has no live
parts, which are accessible. Also ensure that the insulation rating of the source wiring and circuitry is greater than
or equal to the maximum output voltage of the electronic lo ad.
When making connections to the bus bars. Ensure that each terminal’s mounting hardware and wiring assembly
are placed to avoid touching the other terminal and shorting the electronic load input. Heavy connecting cables
must have some form of strain relief to avoid loosening the connections or bending the bus bars.
LOCAL SENSE CONFIGURATION
When the Electronic Loa d is stra pped for loca l sensing, a n una voidable volta ge drop is incurred in the loa d lea ds a nd this
a dds to the load regula tion. Hence, loca l sensing is usua lly used in a pplica tions where the lea d lengths a re rela tively short,
or loa d regu la tion is not critica l. Loca l or remote sense ca n be set by a ccessing:
ME NU
→
LOAD
CONTROL
→
REMOTE SENSE
→
LOCAL
a nd pressing enter button to confirm.
To meet sa fety requirement, loa d wire size should be la rge enough to ca rry e lectric current of the s ource to the Electronic
Load without overheating. Stra nded, copper wires a re recommended. The wires should be la rge enough to limit the
volta ge drop to less tha n 1V per lea d. Refer to Ta ble 2.4 for proper wire size se lection. Input wire connections a re made
to the
"+"
a nd
"-"
termina ls on the rea r pa nel of the Loa d.
FIGURE 2.3 LOCAL SENSE CONFIGURATIONS
WARNING
CAUTION
(-)
(+)
DC Power Supply
_
+
USE THE LARGEST GAUGE,
LOWEST INDUCTANCE AND
SHORTEST LENGTH POSSIBLE
PROGRAMMING
ELECTRONIC
LOAD
–
+
Summary of Contents for Amrel PLA 2U
Page 2: ......
Page 4: ...M470039 01 REV F Page 3 This is page intentionally left blank...
Page 6: ...M470039 01 REV F Page 5 This page intentionally left blank...
Page 8: ...M470039 01 REV F Page 7 This page intentionally left blank...
Page 132: ...M470039 01 REV F Page 131 SEVEN SPECIFICATIONAND POWER CURVE COMMON SPECIFICATIONS...
Page 141: ...M470039 01 REV F Page 140...
Page 161: ......
Page 162: ......