![Agilent Technologies 4284A Operation Manual Download Page 179](http://html.mh-extra.com/html/agilent-technologies/4284a/4284a_operation-manual_2867874179.webp)
Capacitance
T
o
Ground
T
o
measure
capacitors
of
10
pF
or
less,
the
stray
capacitance
(when
the
conductors
are
grounded,
this
is
capacitance
to
ground),
b et
w
een
the
measuremen
t
con
tacts
and
the
conductors
near
the
capacitor
will
inuence
the
measuremen
t,
as
sho
wn
in
Figure
6-8.
Figure
6-8.
Model
of
Capacitance
to
Ground
T
o
minimize
the
stray
capacitance
of
the
test
leads,
the
cen
ter
conductor
of
the
test
leads
should
b e
k
ept
as
short
as
p ossible,
as
sho
wn
in
Figure
6-9
(A).
If
four-terminal
pair
connections
are
close
to
the
p oint
where
con
tact
is
made
with
the
DUT,
in
terconnect
the
shields
of
the
measuremen
t
terminals
to
the
conductor
to
reduce
the
inuence
of
the
stray
capacitance
to
ground,
as
sho
wn
in
Figure
6-9
(B).
Measurement
Procedure
and
Examples
6-11
Summary of Contents for 4284A
Page 12: ......
Page 37: ...Figure 1 1 Power Cable Supplied Installation and Set Up Guide 1 3 ...
Page 54: ...Figure 2 5 Display Pages 1 3 2 12 Overview ...
Page 55: ...Figure 2 5 Display Pages 2 3 Overview 2 13 ...
Page 56: ...Figure 2 5 Display Pages 3 3 2 14 Overview ...
Page 58: ...Figure 2 7 Softkey Selection Example 2 16 Overview ...
Page 60: ...Figure 3 1 Available Fields on the MEAS DISPLAY Page 3 2 DISPLAY FORMAT Menu ...
Page 61: ...Figure 3 2 Available Softkeys on the MEAS DISPLAY Page DISPLAY FORMAT Menu 3 3 ...
Page 66: ...Figure 3 4 Effective Measuring Range Oscillator Level 2V or 20 mA 3 8 DISPLAY FORMAT Menu ...
Page 91: ...Figure 3 15 Available Fields on the LIST SWEEP DISPLAY Page DISPLAY FORMAT Menu 3 33 ...
Page 96: ......
Page 99: ...Figure 4 2 Available Softkeys on the MEAS SETUP Page MEAS SETUP Menu 4 3 ...
Page 104: ...Figure 4 5 Available Operating Area for the ALC Function 4 8 MEAS SETUP Menu ...
Page 113: ...4 Press NNNNNNNNNNN YES to reset the 4284A MEAS SETUP Menu 4 17 ...
Page 115: ...Figure 4 8 Available Fields on the CORRECTION Page MEAS SETUP Menu 4 19 ...
Page 116: ...Figure 4 9 Available Softkeys on the CORRECTION Page 4 20 MEAS SETUP Menu ...
Page 131: ...Figure 4 15 Available Fields on the LIMIT TABLE SETUP Page MEAS SETUP Menu 4 35 ...
Page 145: ...Figure 4 21 Available Fields on the LIST SWEEP SETUP Page MEAS SETUP Menu 4 49 ...
Page 152: ......
Page 158: ...Figure 5 4 Available Fields on the SYSTEM CONFIG Page 5 6 Catalog System Configuration ...
Page 228: ...Figure 7 19 Standard Event Status Register 7 28 Remote Control ...
Page 240: ......
Page 361: ...Caution The memory card should be removed before packing the 4284A General Information 9 29 ...
Page 362: ......
Page 432: ......
Page 436: ......
Page 440: ......
Page 460: ......