166 Parameters
16.11
User IO sel lo
When parameter
is set to
selects the user parameter set together with parameter
. The status of the source defined by this
parameter and parameter
select the user parameter
set as follows:
Const
Bit pointer setting (see
on page
).
-
Pointer
16.12
User IO sel hi
See parameter
.
Const
Bit pointer setting (see
on page
).
-
Pointer
16.14
Reset ChgParLog
Resets the log of latest parameter changes.
Done
Reset not requested (normal operation).
0
Reset
Reset log of latest parameter changes. The value reverts
automatically to
1
16.16
Menu set active
Shows which parameter list is active. Parameter lists
determine which parameters are displayed.
See also parameter
.
None
No specific parameter list is active.
0
Single short
A selective list of parameters relevant to the single pump
(factory default) application macro is displayed.
1
Single long
A more comprehensive list of parameters relevant to the
single pump (factory default) application macro is displayed.
2
Trad short
A selective list of parameters relevant to the traditional pump
control application macro is displayed.
3
Trad long
A more comprehensive list of parameters relevant to the
traditional pump control application macro is displayed.
4
Ext short
A selective list of parameters relevant to the external control
application macro is displayed.
5
Ext long
A more comprehensive list of parameters relevant to the
external control application macro is displayed.
6
H/A short
A selective list of parameters relevant to the Hand/Auto
control application macro is displayed.
7
H/A long
A more comprehensive list of parameters relevant to the
Hand/Auto control application macro is displayed.
8
Level short
A selective list of parameters relevant to the Level control
application macro (single-pump) is displayed.
9
Level long
A more comprehensive list of parameters relevant to the
Level control application macro (single-pump) is displayed.
10
No.
Name/Value
Description
FbEq
Status of source
defined by par.
Status of source
defined by par.
User parameter
set selected
FALSE
FALSE
Set 1
TRUE
FALSE
Set 2
FALSE
TRUE
Set 3
TRUE
TRUE
Set 4
Summary of Contents for ACQ810
Page 1: ...ABB industrial drives Firmware manual Standard pump control program for ACQ810 drives ...
Page 4: ......
Page 14: ...14 About the manual ...
Page 56: ...56 Control locations ...
Page 97: ...Application macros 97 ...
Page 98: ...98 Application macros ...
Page 100: ...100 Application macros ...
Page 101: ...Application macros 101 ...
Page 106: ...106 Application macros 75 01 Operation mode Multipump 76 01 Enable MF comm Yes ...
Page 356: ...356 Control through the embedded fieldbus interface ...
Page 366: ...366 Control through a fieldbus adapter ...
Page 374: ...374 Control block diagrams ...