4.4 Command Option Attachable-type FT82 SERVOPACKs with INDEXER Modules
4-131
4
Parameter Li
s
t
s
PnB00
2
Serial Communication
Protocol
0000h to
0009h
–
0001h
All
After
restart
Setup
*1
PnB01
2
Bit rate
0000h to
0002h
–
0000h
All
After
restart
Setup
*1
PnB02
2
Response “OK”
0000h,
0001h
–
0001h
All
Immedi-
ately
Setup
*1
PnB03
2
/MODE 0/1
0000h to
0003h
–
0000h
All
After
restart
Setup
*1
PnB04
2
/START-STOP; /HOME
0000h to
0003h
–
0000h
All
After
restart
Setup
*1
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
0000h
Full-duplex wiring is used for communications method.
0001h
Full-duplex wiring is used for communications method. Echoback is performed for each
character.
0002h
Half-duplex wiring is used for communications method. CR is used as delimiter.
0003h
Half-duplex wiring is used for communications method. CR is used as delimiter. Echoback
is performed for each character.
0004h
Half-duplex wiring is used for communications method. CR is used as delimiter. Echoback
is performed for each command.
0005h
Half-duplex wiring is used for communications method. CRLF is used as delimiter.
0006h
Half-duplex wiring is used for communications method. CRLF is used as delimiter. Echo-
back is performed for each character.
0007h
Half-duplex wiring is used for communications method. CRLF is used as delimiter. Echo-
back is performed for each command.
0008h,
0009h
Reserved parameter
0000h
Sets bit rate at 9600 bps.
0001h
Sets bit rate at 19200 bps.
0002h
Sets bit rate at 38400 bps.
0000h
Does not return OK response.
0001h
Returns OK response.
0000h
When input signal is ON (closed), mode is set to Mode 0.
0001h
When input signal is OFF (open), mode is set to Mode 0.
0002h
Always Mode 0
0003h
Always Mode 1
0000h
•
When /MODE signal is ON (closed) (mode 0): Start program table operation when the
/START-STOP signal turns ON (closes). Stop program table operation when the /START-
STOP signal turns OFF (opens).
•
When /MODE signal is OFF (open) (mode 1): Turn ON (close) the /HOME signal to start an
origin return.
0001h
•
When /MODE signal is ON (closed) (mode 0): Start program table operation when the
/START-STOP signal turns OFF (opens). Stop program table operation when the /START-
STOP signal turns ON (closes).
•
When /MODE signal is OFF (open) (mode 1): Turn OFF (open) the /HOME signal to start
an origin return.
0002h,
0003h
•
When /MODE signal is ON (closed) (mode 0): Do not use the /START-STOP signal.
•
When /MODE signal is OFF (open) (mode 1): Do not use the /HOME signal.