4.4 Command Option Attachable-type FT82 SERVOPACKs with INDEXER Modules
4-127
4
Parameter Li
s
t
s
Pn418
2
Third Stage Notch Filter
Q Value
50 to 1,000
0.01
70
All
Immedi-
ately
Tuning
*1
Pn419
2
Third Stage Notch Filter
Depth
0 to 1,000
0.001
0
All
Immedi-
ately
Tuning
*1
Pn41A
2
Fourth Stage Notch Fil-
ter Frequency
50 to 5,000
1 Hz
5000
All
Immedi-
ately
Tuning
*1
Pn41B
2
Fourth Stage Notch Fil-
ter Q Value
50 to 1,000
0.01
70
All
Immedi-
ately
Tuning
*1
Pn41C
2
Fourth Stage Notch Fil-
ter Depth
0 to 1,000
0.001
0
All
Immedi-
ately
Tuning
*1
Pn41D
2
Fifth Stage Notch Filter
Frequency
50 to 5,000
1 Hz
5000
All
Immedi-
ately
Tuning
*1
Pn41E
2
Fifth Stage Notch Filter
Q Value
50 to 1,000
0.01
70
All
Immedi-
ately
Tuning
*1
Pn41F
2
Fifth Stage Notch Filter
Depth
0 to 1,000
0.001
0
All
Immedi-
ately
Tuning
*1
Pn423
2
Speed Ripple Compen-
sation Selections
0000h to
1111h
–
0000h
Rotary
–
Setup
*1
Pn424
2
Torque Limit at Main Cir-
cuit Voltage Drop
0 to 100
1%
*4
50
All
Immedi-
ately
Setup
*1
Pn425
2
Release Time for Torque
Limit at Main Circuit
Voltage Drop
0 to 1,000
1 ms
100
All
Immedi-
ately
Setup
*1
Pn426
2
Reserved parameter (Do
not change.)
–
–
0
All
–
–
–
Pn427
2
Speed Ripple Compen-
sation Enable Speed
0 to 10,000
1 min
-1
0
Rotary Ser-
vomotor
Immedi-
ately
Tuning
*1
Pn456
2
Sweep Torque Refer-
ence Amplitude
1 to 800
1%
15
All
Immedi-
ately
Tuning
*1
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Speed Ripple Compensation Function Selection
When
Enabled
0
Disable speed ripple compensation.
Immedi-
ately
1
Enable speed ripple compensation.
n.
X
Speed Ripple Compensation Information Disagreement Warning Detec-
tion Selection
When
Enabled
0
Detect A.942 alarms.
After
restart
1
Do not detect A.942 alarms.
n.
X
Speed Ripple Compensation Enable Condition Selection
When
Enabled
0
Speed reference
After
restart
1
Motor speed
n.X
Reserved parameter (Do not change.)