3.5 FT83 SERVOPACKs with Analog Voltage/Pulse Train References
3.5.8 INDEXER Warning Displays and Troubleshooting
3-246
E4DE
A.9F9
Moving Disabled
Error due to P-LS
The specified target position exceeds the
position reference of forward software limit
set in Pn638.
•
Check the tar-
get position
specification.
•
Check the for-
ward software
limit in Pn638.
•
Check the Mov-
ing Mode (rota-
tional/linear
coordinates)
(Pn637=
n.
X)
•
If the software
limits are not
being used,
select rotational
coordinates with
Pn637=
n.
X (Mov-
ing Mode) or dis-
able the
software limits
by setting Pn638
= Pn63A = 0.
E4EE
A.9F9
Moving Disabled
Error due to N-LS
The specified target position exceeds the
position reference of reverse software limit
set in Pn63A.
•
Check the tar-
get position
specification.
•
Check the
reverse soft-
ware limit in
Pn63A.
•
Check the set-
ting of the Mov-
ing Mode
(rotational/linear
coordinates)
(Pn637=
n.
X).
•
If the software
limits are not
being used,
select rotational
coordinates for
the (i.e., set
Pn637 to
n.
1) or dis-
able the soft-
ware limits by
setting Pn638 =
Pn63A = 0.
E4FE
A.9F9
Position Refer-
ence Out-of-range
Error
The Moving Mode is set to rotational coordi-
nates (i.e., Pn637 is not set to n.
0) and
the target position designation exceeded the
position range setting (Pn638 and Pn63A).
•
Check the tar-
get position
specification.
•
Check the posi-
tioning range set
with Pn638 and
Pn63A.
•
Check the set-
ting of the Mov-
ing Mode
(rotational/linear
coordinates)
(Pn637=
n.
X).
Continued on next page.
Continued from previous page.
Error No.
Alarm
Number
Error Name
Meaning
Corrective Action