4.2 FT82 SERVOPACK with MECHATROLINK-II Communications References
4
Parameter Li
s
t
s
4-53
Pn516
2
Input Signal Selections
7
0000h to
FFFFh
–
8888h
All
After
restart
Setup
–
Pn518
*4
–
Safety Module-Related
Parameters
–
–
–
All
–
–
–
Pn51B
4
Motor-Load Position
Deviation Overflow
Detection Level
0 to
1,073,741,824
1 refer-
ence
unit
1000
Rotary
Immedi-
ately
Setup
*1
Pn51E
2
Position Deviation Over-
flow Warning Level
10 to 100
1%
100
All
Immedi-
ately
Setup
*1
Pn520
4
Position Deviation Over-
flow Alarm Level
1 to
1,073,741,823
1 refer-
ence
unit
524288
0
All
Immedi-
ately
Setup
*1
Pn522
4
Positioning Completed
Width
0 to
1,073,741,824
1 refer-
ence
unit
7
All
Immedi-
ately
Setup
*1
Pn524
4
Near Signal Width
1 to
1,073,741,824
1 refer-
ence
unit
107374
1824
All
Immedi-
ately
Setup
*1
Pn526
4
Position Deviation Over-
flow Alarm Level at
Servo ON
1 to
1,073,741,823
1 refer-
ence
unit
524288
0
All
Immedi-
ately
Setup
*1
Pn528
2
Position Deviation Over-
flow Warning Level at
Servo ON
10 to 100
1%
100
All
Immedi-
ately
Setup
*1
Pn529
2
Speed Limit Level at
Servo ON
0 to 10,000
1 min
-1
10000
Rotary
Immedi-
ately
Setup
*1
Pn52A
2
Multiplier per Fully-
closed Rotation
0 to 100
1%
20
Rotary
Immedi-
ately
Tuning
*1
Pn52B
2
Overload Warning Level
1 to 100
1%
20
All
Immedi-
ately
Setup
*1
Continued on next page.
Continued from previous page.
Parameter
No.
Siz
e
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
FSTP (Forced Stop Input) Signal Allocation
Reference
0
Enable drive when CN1-13 input signal is ON (closed).
*1
1
Enable drive when CN1-7 input signal is ON (closed).
2
Enable drive when CN1-8 input signal is ON (closed).
3
Enable drive when CN1-9 input signal is ON (closed).
4
Enable drive when CN1-10 input signal is ON (closed).
5
Enable drive when CN1-11 input signal is ON (closed).
6
Enable drive when CN1-12 input signal is ON (closed).
7
Set the signal to always prohibit drive (always force the motor to
stop).
8
Set the signal to always enable drive (always disable forcing the
motor to stop).
9
Enable drive when CN1-13 input signal is OFF (open).
A
Enable drive when CN1-7 input signal is OFF (open).
B
Enable drive when CN1-8 input signal is OFF (open).
C
Enable drive when CN1-9 input signal is OFF (open).
D
Enable drive when CN1-10 input signal is OFF (open).
E
Enable drive when CN1-11 input signal is OFF (open).
F
Enable drive when CN1-12 input signal is OFF (open).
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)