![YASKAWA SGM7D-30F Скачать руководство пользователя страница 496](http://html1.mh-extra.com/html/yaskawa/sgm7d-30f/sgm7d-30f_product-manual_3686891496.webp)
4.5 FT83 SERVOPACKs with Analog Voltage/Pulse Train References
4-171
4
Parameter Li
s
t
s
Pn635
2
Output Signal Selec-
tions 10
0000h to
6666h
–
0654h
All
After
restart
Setup
−
Pn636
2
Output Signal Selec-
tions 11
0000h to
0666h
–
0000h
All
After
restart
Setup
−
Continued on next page.
Continued from previous page.
Parameter
No.
Siz
e
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
/POUT0 (Programmable Output 0) Signal Allocation
Reference
0
Disabled (the above signal output is not used).
*1
1
Output the signal from the CN1-25 or CN1-26 output terminal.
2
Output the signal from the CN1-27 or CN1-28 output terminal.
3
Output the signal from the CN1-29 or CN1-30 output terminal.
4
Output the signal from the CN1-37 output terminal.
5
Output the signal from the CN1-38 output terminal.
6
Output the signal from the CN1-39 output terminal.
n.
X
/POUT1 (Programmable Output 1) Signal Allocation
Reference
0 to 6
The settings are the same as for /POUT0 (Programmable Output
0) Signal Allocation.
*1
n.
X
/POUT2 (Programmable Output 2) Signal Allocation
Reference
0 to 6
The settings are the same as for /POUT0 (Programmable Output
0) Signal Allocation.
*1
n.X
/POUT3 (Programmable Output 3) Signal Allocation
Reference
0 to 6
The settings are the same as for /POUT0 (Programmable Output
0) Signal Allocation.
*1
n.
X
/POUT4 (Programmable Output 4) Signal Allocation
Reference
0
Disabled (the above signal output is not used).
*1
1
Output the signal from the CN1-25 or CN1-26 output terminal.
2
Output the signal from the CN1-27 or CN1-28 output terminal.
3
Output the signal from the CN1-29 or CN1-30 output terminal.
4
Output the signal from the CN1-37 output terminal.
5
Output the signal from the CN1-38 output terminal.
6
Output the signal from the CN1-39 output terminal.
n.
X
/POSRDY (Origin Return Completed Output) Signal Allocation
Reference
0 to 6
The settings are the same as for /POUT4 (Programmable Output
4) Signal Allocation.
*1
n.
X
/DEN (Positioning Reference Distribution Output) Signal Allocation
Reference
0 to 6
The settings are the same as for /POUT4 (Programmable Output
4) Signal Allocation.
*1
n.X
Reserved parameter (Do not change.)