4.5 FT83 SERVOPACKs with Analog Voltage/Pulse Train References
4-153
4
Parameter Li
s
t
s
Pn307
2
Speed Reference Filter
Time Constant
0 to 65,535
0.01 ms
40
All
Immedi-
ately
Setup
*1
Pn308
2
Speed Feedback Filter
Time Constant
0 to 65,535
0.01 ms
0
All
Immedi-
ately
Setup
*1
Pn30A
2
Deceleration Time for
Servo OFF and Forced
Stops
0 to 10,000
1 ms
0
All
Immedi-
ately
Setup
*1
Pn30C
2
Speed Feedforward
Average Movement
Time
0 to 5,100
0.1 ms
0
All
Immedi-
ately
Setup
*1
Pn310
2
Vibration Detection
Selections
0000h to
0002h
–
0000h
All
Immedi-
ately
Setup
*1
Pn311
2
Vibration Detection Sen-
sitivity
50 to 500
1%
100
All
Immedi-
ately
Tuning
*1
Pn312
2
Vibration Detection
Level
0 to 5,000
1 min
-1
50
Rotary
Immedi-
ately
Tuning
*1
Pn316
2
Maximum Motor Speed
0 to 65,535
1 min
-1
10000
Rotary
After
restart
Setup
*1
Pn324
2
Moment of Inertia Cal-
culation Starting Level
0 to 20,000
1%
300
All
Immedi-
ately
Setup
*1
Pn400
2
Torque Reference Input
Gain
10 to 100
0.1 V/
rated
torque
30
All
Immedi-
ately
Setup
*1
Pn401
2
First Stage First Torque
Reference Filter Time
Constant
0 to 65,535
0.01 ms
100
All
Immedi-
ately
Tuning
*1
Pn402
2
Forward Torque Limit
0 to 800
1%
*2
800
Rotary
Immedi-
ately
Setup
*1
Pn403
2
Reverse Torque Limit
0 to 800
1%
*2
800
Rotary
Immedi-
ately
Setup
*1
Pn404
2
Forward External Torque
Limit
0 to 800
1%
*2
100
All
Immedi-
ately
Setup
*1
Pn405
2
Reverse External Torque
Limit
0 to 800
1%
*2
100
All
Immedi-
ately
Setup
*1
Pn406
2
Emergency Stop Torque
0 to 800
1%
*2
800
All
Immedi-
ately
Setup
*1
Pn407
2
Speed Limit during
Torque Control
0 to 10,000
1 min
-1
10000
Rotary
Immedi-
ately
Setup
*1
Continued on next page.
Continued from previous page.
Parameter
No.
Siz
e
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Vibration Detection Selection
0
Do not detect vibration.
1
Output a warning (A.911) if vibration is detected.
2
Output an alarm (A.520) if vibration is detected.
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)