4.5 FT83 SERVOPACKs with Analog Voltage/Pulse Train References
4-173
4
Parameter Li
s
t
s
*1.
Refer to the following manual for details.
Σ
-7-Series
Σ
-7S SERVOPACK with Analog Voltage/Pulse Train References Product Manual
(Manual No.: SIEP S800001 26)
*2.
Set a percentage of the rated motor torque.
*3.
These parameters are for SERVOPACKs with a Safety Module. Refer to the following manual for details.
Σ
-V-Series/
Σ
-V-Series for Large-Capacity Models/
Σ
-7-Series User’s Manual Safety Module
(Manual No.: SIEP C720829 06)
*4.
Normally set this parameter to 0. If you use an External Regenerative Resistor, set the capacity (W) of the Exter-
nal Regenerative Resistor.
*5.
The upper limit is the maximum output capacity (W) of the SERVOPACK.
*6.
These parameters are for SERVOPACKs with the Dynamic Brake Option. Refer to the following manual for
details.
Σ
-7-Series AC Servo Drive
Σ
-7S/S-7W SERVOPACK with Dynamic Brake Hardware Option Specifications Prod-
uct Manual (Manual No.: SIEP S800001 73)
*7.
The SGLFW2 is the only Yaskawa Linear Servomotor that supports this function.
*8.
Enabled only when Pn61A is set to n.
2 or n.
3.
*9.
Refer to the following manual for details.
Σ
-7-Series
Σ
-7S SERVOPACK with FT/EX Specification for Indexing Application Product Manual
(Manual No.: SIEP S800001 84)
Pn643
2
Origin Return Direction
0000h to
0001h
–
0000h
All
Immedi-
ately
–
–
Pn644
4
Origin Return Movement
Speed
1 to
199,999,999
1,000
refer-
ence
units/
min
-1
1000
All
Immedi-
ately
Setup
*1
Pn646
4
Origin Approach Speed
1 to
199,999,999
1,000
refer-
ence
units/
min
-1
1000
All
Immedi-
ately
Setup
*1
Pn648
4
Origin Return Creep
Speed
1 to
199,999,999
1,000
refer-
ence
units/
min
-1
1000
All
Immedi-
ately
Setup
*1
Pn64A
4
Origin Return Final
Travel Distance
-1,073,741,823
to
+1,073,741,823
Refer-
ence
units
0
All
Immedi-
ately
Setup
*1
Pn64C
2
Zone Signal Setting
0000h to
0001h
–
0000h
All
After
restart
Setup
–
Pn64D
2
Reserved parameter (Do
not change.)
–
–
0000h
–
–
–
–
Continued from previous page.
Parameter
No.
Siz
e
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Origin Return Direction
Reference
0
When the /HOME signal turns ON, an origin return is performed
in the forward direction.
*1
1
When the /HOME signal turns ON, an origin return is performed
in the reverse direction.
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
n.
X
Zone Signal Setting
Reference
0
When the control power supply is turned ON or the SERVOPACK
is reset, the /POUT0 to /POUT2 signals are inactive.
*1
1
When the control power supply is turned ON or the SERVOPACK
is reset, the /POUT0 to /POUT2 signals are used as zone signals.
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)