4.5 FT83 SERVOPACKs with Analog Voltage/Pulse Train References
4-140
Pn001
2
Application Function
Selections 1
0000h to
1142h
–
0000h
All
After
restart
Setup
–
Continued on next page.
Continued from previous page.
Parameter
No.
Siz
e
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Motor Stopping Method for Servo OFF and Group 1 Alarms
Reference
0
Stop the motor by applying the dynamic brake.
*1
1
Stop the motor by the applying dynamic brake and then release
the dynamic brake.
2
Coast the motor to a stop without the dynamic brake.
n.
X
Overtravel Stopping Method
Reference
0
Apply the dynamic brake or coast the motor to a stop (use the
stopping method set in Pn001 = n.
X).
*1
1
Decelerate the motor to a stop using the torque set in Pn406 as
the maximum torque and then servo-lock the motor.
2
Decelerate the motor to a stop using the torque set in Pn406 as
the maximum torque and then let the motor coast.
3
Decelerate the motor to a stop using the deceleration time set in
Pn30A and then servo-lock the motor.
4
Decelerate the motor to a stop using the deceleration time set in
Pn30A and then let the motor coast.
n.
X
Main Circuit Power Supply AC/DC Input Selection
Reference
0
Input AC power as the main circuit power supply using the L1, L2,
and L3 terminals (do not use shared converter).
*1
1
Input DC power as the main circuit power supply using the B1/
and
2 terminals or the B1 and
2 terminals (use an external
converter or the shared converter).
n.X
Warning Code Output Selection
Reference
0
Output only alarm codes on the ALO1, ALO2, and ALO3 termi-
nals.
*1
1
Output both warning codes and alarm codes on the ALO1, ALO2,
and ALO3 terminals. However, while an warning code is being
output, the ALM (Servo Alarm) output signal will remain ON (nor-
mal state).