4.1 FT82 SERVOPACKs with Analog Voltage/Pulse Train References
4-14
Pn200
2
Position Control Refer-
ence For Selections
0000h to
2236h
–
0000h
All
After
restart
Setup
–
Pn205
2
Multiturn Limit
0 to 65,535
1 rev
65535
Rotary
After
restart
Setup
*1
Pn207
2
Position Control Func-
tion Selections
0000h to
2210h
–
0000h
All
After
restart
Setup
–
Continued on next page.
Continued from previous page.
Parameter
No.
Siz
e
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Reference Pulse Form
Reference
0
Sign and pulse train, positive logic.
*1
1
CW and CCW pulse trains, positive logic
2
Two-phase pulse trains with 90
°
phase differential (phase A and
phase B)
×
1, positive logic
3
Two-phase pulse trains with 90
°
phase differential (phase A and
phase B)
×
2, positive logic
4
Two-phase pulse trains with 90
°
phase differential (phase A and
phase B)
×
4, positive logic
5
Sign and pulse train, negative logic.
6
CW and CCW pulse trains, negative logic
n.
X
Clear Signal Form
Reference
0
Clear position deviation when the signal is at high level.
*1
1
Clear position deviation on the rising edge of the signal.
2
Clear position deviation when the signal is at low level.
3
Clear position deviation on the falling edge of the signal.
n.
X
Clear Operation
Reference
0
Clear position deviation at a base block (at servo OFF or when
alarm occurs).
*1
1
Do not clear position error (cleared only with CLR (Clear Position
Deviation) signal).
2
Clear position deviation when an alarm occurs.
n.X
Filter Selection
Reference
0
Use the reference input filter for a line-driver signal. (1 Mpps max.)
*1
1
Use the reference input filter for an open-collector signal. (200
kpps max.)
2
Use reference input filter 2 for a line-driver signal. (1 to 4 Mpps)
n.
X
Reserved parameter (Do not change.)
n.
X
Position Control Option
Reference
0
Do not use V-REF.
*1
1
Use V-REF as a speed feedback input.
n.
X
Reserved parameter (Do not change.)
n.X
/COIN (Positioning Completion Output) Signal Output Timing
Refer-
ence
0
Output when the absolute value of the position deviation is the
same or less than the setting of Pn522 (Positioning Completed
Width).
*1
1
Output when the absolute value of the position error is the same
or less than the setting of Pn522 (Positioning Completed Width)
and the reference after the position reference filter is 0.
2
Output when the absolute value of the position error is the same
or less than the setting of Pn522 (Positioning Completed Width)
and the reference input is 0.