![YASKAWA SGM7D-30F Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/yaskawa/sgm7d-30f/sgm7d-30f_product-manual_3686891044.webp)
1.4 Functions
1.4.2 Function Application Restrictions
1-10
1.4.2
Function Application Restrictions
The following functional restrictions apply when you use the FT82/FT83 SERVOPACKs.
Function
Restriction
Setting the Linear Encoder Pitch
Cannot be used.
Writing Linear Servomotor Param-
eters
Cannot be used.
Selecting the Phase Sequence for
a Linear Servomotor
Cannot be used.
Polarity Sensor Setting
Cannot be used.
Polarity Detection
Cannot be used.
Speed Ripple Compensation
Cannot be used.
Do not change the following default setting: Pn423 = n.
0.
Tuning-less Function
Cannot be used if the load moment of inertia ratio is 10 or greater.