4.4 Command Option Attachable-type FT82 SERVOPACKs with INDEXER Modules
4-122
Pn140
2
Model Following Con-
trol-Related Selections
0000h to
1121h
–
0100h
All
Immedi-
ately
Tuning
–
Pn141
2
Model Following Con-
trol Gain
10 to 20,000
0.1/s
500
All
Immedi-
ately
Tuning
*1
Pn142
2
Model Following Con-
trol Gain Correction
500 to 2,000
0.1%
1000
All
Immedi-
ately
Tuning
*1
Pn143
2
Model Following Con-
trol Bias in the Forward
Direction
0 to 10,000
0.1%
1000
All
Immedi-
ately
Tuning
*1
Pn144
2
Model Following Con-
trol Bias in the Reverse
Direction
0 to 10,000
0.1%
1000
All
Immedi-
ately
Tuning
*1
Pn145
2
Vibration Suppression 1
Frequency A
10 to 2,500
0.1 Hz
500
All
Immedi-
ately
Tuning
*1
Pn146
2
Vibration Suppression 1
Frequency B
10 to 2,500
0.1 Hz
700
All
Immedi-
ately
Tuning
*1
Pn147
2
Model Following Con-
trol Speed Feedforward
Compensation
0 to 10,000
0.1%
1000
All
Immedi-
ately
Tuning
*1
Pn148
2
Second Model Follow-
ing Control Gain
10 to 20,000
0.1/s
500
All
Immedi-
ately
Tuning
*1
Pn149
2
Second Model Follow-
ing Control Gain Correc-
tion
500 to 2,000
0.1%
1000
All
Immedi-
ately
Tuning
*1
Pn14A
2
Vibration Suppression 2
Frequency
10 to 2,000
0.1 Hz
800
All
Immedi-
ately
Tuning
*1
Pn14B
2
Vibration Suppression 2
Correction
10 to 1,000
1%
100
All
Immedi-
ately
Tuning
*1
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Model Following Control Selection
Reference
0
Do not use model following control.
*1
1
Use model following control.
n.
X
Vibration Suppression Selection
Reference
0
Do not perform vibration suppression.
*1
1
Perform vibration suppression for a specific frequency.
2
Perform vibration suppression for two specific frequencies.
n.
X
Vibration Suppression Adjustment Selection
Reference
0
Do not adjust vibration suppression automatically during execu-
tion of autotuning without a host reference, autotuning with a host
reference, and custom tuning.
*1
1
Adjust vibration suppression automatically during execution of
autotuning without a host reference, autotuning with a host refer-
ence, and custom tuning.
n.X
Reserved parameter (Do not change.)