4.2 FT82 SERVOPACK with MECHATROLINK-II Communications References
4-56
Pn801
2
Application Function
Selections 6 (Software
Limits)
0000h to
0103h
–
0003h
All
Immedi-
ately
Setup
*1
Pn803
2
Origin Range
0 to 250
1 refer-
ence
unit
10
All
Immedi-
ately
Setup
*2
Pn804
4
Forward Software Limit
-1,073,741,823
to
1,073,741,823
1 refer-
ence
unit
107374
1823
All
Immedi-
ately
Setup
*1
Pn806
4
Reverse Software Limit
-1,073,741,823
to
1,073,741,823
1 refer-
ence
unit
-10737
41823
All
Immedi-
ately
Setup
*1
Pn808
4
Absolute Encoder Origin
Offset
-1,073,741,823
to
1,073,741,823
1 refer-
ence
unit
0
All
Immedi-
ately
*10
Setup
*1
Pn80A
2
First Stage Linear Accel-
eration Constant
1 to 65,535
10,000
refer-
ence
units/s
2
100
All
Immedi-
ately
*11
Setup
*2
Pn80B
2
Second Stage Linear
Acceleration Constant
1 to 65,535
10,000
refer-
ence
units/s
2
100
All
Immedi-
ately
*11
Setup
*2
Pn80C
2
Acceleration Constant
Switching Speed
0 to 65,535
100 ref-
erence
units/s
0
All
Immedi-
ately
*11
Setup
*2
Pn80D
2
First Stage Linear
Deceleration Constant
1 to 65,535
10,000
refer-
ence
units/s
2
100
All
Immedi-
ately
*11
Setup
*2
Pn80E
2
Second Stage Linear
Deceleration Constant
1 to 65,535
10,000
refer-
ence
units/s
2
100
All
Immedi-
ately
*11
Setup
*2
Pn80F
2
Deceleration Constant
Switching Speed
0 to 65,535
100 ref-
erence
units/s
0
All
Immedi-
ately
*11
Setup
*2
Pn810
2
Exponential Accelera-
tion/Deceleration Bias
0 to 65,535
100 ref-
erence
units/s
0
All
Immedi-
ately
*12
Setup
*2
Pn811
2
Exponential Accelera-
tion/Deceleration Time
Constant
0 to 5,100
0.1 ms
0
All
Immedi-
ately
*12
Setup
*2
Pn812
2
Movement Average
Time
0 to 5,100
0.1 ms
0
All
Immedi-
ately
*12
Setup
*2
Pn814
4
External Positioning
Final Travel Distance
-1,073,741,823
to
1,073,741,823
1 refer-
ence
unit
100
All
Immedi-
ately
Setup
*2
Continued on next page.
Continued from previous page.
Parameter
No.
Siz
e
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Software Limit Selection
0
Enable both forward and reverse software limits.
1
Disable forward software limit.
2
Disable reverse software limit.
3
Disable both forward and reverse software limits.
n.
X
Reserved parameter (Do not change.)
n.
X
Software Limit Check for References
0
Do not perform software limit checks for references.
1
Perform software limit checks for references.
n.X