3.5 FT83 SERVOPACKs with Analog Voltage/Pulse Train References
3.5.8 INDEXER Warning Displays and Troubleshooting
3-248
E5EE
A.9F9
Execution Dis-
abled during Pro-
gram Table
Operation Error
•
There was a request to execute a process
that is not allowed during program table
operation while program table operation
was in progress or on hold.
•
There was an attempt to change the pro-
gram table while program table operation
was in progress or on hold.
Request execution
of the process
again after cancel-
ing program table
operation by turn-
ing the
/PGMRES signal
ON.
E5FE
A.9F9
Session Conflict
Error
There was a request that could not be exe-
cuted at the same time as the function that
was being executed.
Example:
There was a request to start program table
operation while the program table was being
initialized.
Execute the oper-
ation again after
the execution of
the current func-
tion is completed.
E63E
A.9F9
Continuous Stop
Execution Dis-
abled Error
An attempt was made to execute a continu-
ous stop under conditions where it could not
be executed.
Examples:
•
The coordinates have been set to linear
moving method.
•
The immediately-preceding table target
position is not
±
INFINITE.
•
The immediately-preceding table target
position is
±
INFINITE, but the registration
distance is set.
•
A value other than 1 has been set for the
execution count.
Execute a continu-
ous stop under
conditions where
it can be exe-
cuted.
Continued from previous page.
Error No.
Alarm
Number
Error Name
Meaning
Corrective Action